Working the boiler
Adjust the ambient thermostat to the required temperature (approx.
20 °C). If there is a demand for heating water, the boiler starts
and the
symbol is shown on the display (fig. 24). The boiler will
remain working until the set temperatures are reached, after which
it will go on stand-by. In the event of ignition or operating faults,
the boiler will perform a "safety stop".
The flame symbol
will go out and the fault code and
be displayed (fig. 25). For a description of faults and how to reset
them, consult chapter "Troubleshooting".
24
25

Switching off

Switching off for short periods
For brief absences press the
display will show two segments in the central area (fig. 17). When
the boiler remains powered with the gas tap open, it is protected
by the following systems:
- anti-freeze (fig. 26): when the temperature of the water in the
boiler falls below safety values, the circulator and the burner
work at minimum power to increase the water temperature to a
safe value (35 °C). The
26
- circulator anti-block: one operating cycle is performed every
24 hours.
Switching off for long periods
For prolonged absences press the
(fig. 17). The display will show two segments in the central area.
Turn the main switch to "off".
Turn off the gas tap under the boiler by turning it clockwise (fig. 27).
tap
closed
27
In this case, the anti-freeze and anti-block systems are disabled.
Empty the water circuit or suitably protect it with a good make
of anti-freeze. Drain the domestic hot water circuit.
1 2
1 2
1 2
1 2
1 2
B
button to switch off the boiler. The
symbol lights up on the display.
button to switch off the boiler
Boiler functions
Semi-automatic filling
The boiler features a semi-automatic filling device which turns on
by pressing the
shown on the display (fig. 28).
28
If this condition occurs it means that the system is incorrectly
pressurised though the boiler will continue to work regularly.
will
Press the circuit filling button
Press the circuit filling button
filling sequence. During filling, the drops of the circuit filling
symbol
and the growing pressure value appear on the
display in a cascade sequence (fig. 29).
29
After filling, the
symbol is displayed for a few moments and then
turns off.
Note
During filling, the boiler does not perform other functions. For
example, if there is a request for domestic hot water, the boiler is
unable to provide it until filling has finished.
Note
If circuit pressure reaches 0.6 bar, the pressure value flashes on
the display (fig. 30a); if it falls below a minimum safety value (0.3
bar), fault code 41 appears on the display (fig. 30b) for a certain
time, following which, if the fault persists, fault code 40 is displayed
(see chapter on "Troubleshooting").
30a
30b
In the event of fault 40, press
the circuit. After correcting fault 40, the boiler runs an automatic
vent cycle lasting about 2 minutes; the display reads "SF" (fig.
31) and the "function selectors"
the
button to interrupt the automatic venting
have to fill the system several times, contact the Technical Service
Centre to check whether the heating circuit is watertight (see if
there are any leaks).
31
button when the corresponding symbol
to start-up the filling sequence.
a second time to interrupt the
to reset and then
light up in sequence. Press
is
to start filling
cycle.
If you