Type Label; Before Installation; Installation Position - Burkert 6203 EV Manuel D'utilisation

Électrovanne 2/2 voies
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Operating duration
Unless otherwise indicated on the type label, the solenoid
system is suitable for continuous operation.
Important information for functional reliability during
continuous operation!
For long switch-on or switch-off times a minimum
actuation of 1-2 switching operations per day is
recommended.
Service life
High switching frequency and high pressures reduce the
service life.
english
12
7.
insTallaTiOn
7.1. safety instructions
Danger!
Risk of injury from high pressure in the equipment!
• Before loosening the lines and valves, turn off the
pressure and vent the lines.
Risk of injury due to electrical shock!
• Before reaching into the system , switch off the power
supply and secure to prevent reactivation!
• Observe applicable accident prevention and safety
regulations for electrical equipment!
Warning!
Risk of injury from improper installation!
• Installation may only be carried out by authorized tech-
nicians with the appropriate tools!
Risk of injury from unintentional activation of the
system and an uncontrolled restart!
• Secure system from unintentional activation.
• Following assembly, ensure a controlled restart.
english
14

6.2. Type label

Housing material
Seal material
Orifice
Operating principle
Type
6203
A 10 EPDM MS
G3/8
P N0 - 10bar
230V
50Hz
00229009
Identification number
Manufacturer code
Voltage, Frequency, Power
consumption
Connection thread, Nominal pressure
Fig. 1:
Location and description of the type label

7.2. before installation

Installation position:

Installation can be in any position.
Preferably: Drive at the top.
Prior to installation check pipelines for dirt and if
required, clean.
Dirt filter: To ensure that the solenoid valve functions
reliably, a dirt filter (≤ 500 μm) must be installed in front of
the valve inlet.
7.3. installation
Hold the device with a suitable tool (open-end wrench)
on the housing and screw into the pipeline.
note!
Caution risk of breakage!
• Do not use the coil as a lifting arm.
Observe direction of flow:
The arrow on the housing indicates the direction of
flow.
Type 6203 EV
8W
W14 LU
english
13
english
15