Location of Ice Machine
The location selected for the ice machine must meet the
following criteria. If any of these criteria are not met,
select another location.
•
The location must be free of airborne and other
contaminants.
•
The air temperature must be at least 35°F (1.6°C),
but must not exceed 110°F (43.4°C).
•
Remote air cooled - The air temperature must be at
least -20°F (-29°C), but must not exceed 120°F
(49°C).
•
The location must not be near heat-generating
equipment or in direct sunlight and must be protected
from weather.
•
The location must not obstruct air flow through or
around the ice machine. Refer to the chart below for
clearance requirements.
Part Number 000006520 11/11
Section 2
Installation Instructions
Clearance Requirements
S300
Top/Sides
Back
S320/S450/S500/
S600/S850/S1000
Top/Sides
Back
S420
Top/Sides
Back
S500
230/50/1 Tropical Rating
Top
Sides/Back
S1200
Top
Sides
S1400/S1600/S1800
Top/Sides
Back
S3300**
Top/Sides
Back
*There is no minimum clearance required for water-cooled or
remote ice machines. This value is recommended for efficient
operation and servicing only.
**S3300 - 24" on all sides is recommended to allow access without
moving the bin/ice machine.
! Caution
The ice machine must be protected if it will be
subjected to temperatures below 32°F (0°C). Failure
caused by exposure to freezing temperatures is not
covered by the warranty.
Self-Contained
Self-Contained
Air-Cooled
Water-Cooled
16" (40.6 cm)
8" (20.3 cm)
5" (12.7 cm)
5" (12.7 cm)
Self-Contained
Water-Cooled
Air-Cooled
and Remote*
8" (20.3 cm)
8" (20.3 cm)
5" (12.7 cm)
5" (12.7 cm)
Self-Contained
Water-Cooled
Air-Cooled
and Remote*
12" (30.5 cm)
8" (20.3 cm)
5" (12.7 cm)
5" (12.7 cm)
Self-Contained Air-Cooled
24" (61 cm)
12" (30.5 cm)
Self-Contained
Water-Cooled
Air-Cooled
and Remote*
8" (20.3 cm)
8" (20.3 cm)
12" (30.5 cm)
8" (20.3 cm)
Self-Contained
Water-Cooled
Air-Cooled
and Remote*
24" (61.0 cm)
8" (20.3 cm)
12" (30.5 cm)
5" (12.7 cm)
Water-Cooled
8" (20.3 cm)
24" (61.0 cm)
5