4 Installation
Screws and screwed connections
Unless otherwise specified, a friction coefficient of 0.14 is required for all screwed connections.
Unless otherwise specified, a strength class of 8.8 (metric) or grade 5 (imperial) is required for
all screws.
The screws must be secured against loosening as described in chapter
Screw Retention [} 36].
NOTICE
4.1.2 Dimensions and Mounting Steps
NOTICE
32 - EN
Tools
For assembly, use only checked and calibrated tools subjected to a
quality system.
Reference to the data sheet
The technical drawing with complete dimensioning can be found in
the data sheets of the corresponding variant of the device, for special
versions in the.corresponding customer drawing of the product.
The illustrations below only show a selection of examples. All values
without unit in the picture are given in mm [inch].
In order to simplify the drawings and information, unless otherwise
specified, the general tolerances with tolerance class m (medium) ac-
cording to ISO 2768-1 apply.
BA Ants LEB02 - R60074.0009 - 02
Kübler Group
126593931