Technical Data; Sensor - Kübler Ants LEB02 Instructions D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Kübler Group
11 CE marking

3.2 Technical Data

NOTICE
Extracts of the main technical data are listed below. All other characteristic values can be found
in the corresponding product data sheets.

3.2.1 Sensor

Mechanical characteristics sensor
Operating temperature
Storage temperature
Protection level according to EN 60529 IP54
Air humidity
Installation height
Material Housing
Weight
Maximum measuring length
Maximum speed
Resolution
Accuracy
Electrical characteristics sensor
Supply voltage
Supply voltage according to UL 1310
Supply voltage according to EN 60950
Current consumption
Protection class according to EN 61140 III
EMC
Relevant Standards
UL - Underwriters Laboratories
UL approval
Relevant Standards
BA Ants LEB02 - R60074.0009 - 02
Observe the configuration
The performance characteristics and the mechanical design of the
product depend on the selected configuration (according to order
code).
-10 °C ... +70 °C [14 °F ... 158 °F]
-20 °C ... +80 °C [-4 °F ... 176 °F]
< 90 % (non-condensing)
< 2000 m [6562 ft]
Aluminum
appr. 0.55 kg [19.40 oz]
392 m [1286 ft]
8 m/s [26.25 ft/s]
1 mm
± 1 mm
10 ... 30 V DC
Class 2
PELV
max. 100 mA
EN 12015:2014
EN 12016:2013
File E498900
UL 508
12 Serial number
3 Product Description
EN - 29

Publicité

Table des Matières
loading

Table des Matières