5-1. Serial Number And Rating Label Location
The serial number and rating information is located on the front of the unit. Use rating label to determine input power requirements and/or rated
output. For future reference, write serial number in space provided on back cover of this manual.

5-2. Selecting A Location

5-1.
Selecting a location
18 in.
(460 mm)
OM-239025 Page 14
SECTION 5 – INSTALLATION
4
2
!
Only qualified persons should in-
stall, operate, maintain, and re-
pair this unit.
!
Installation must meet all Nation-
al, State, and Local Codes
only qualified persons make this
installation.
!
Do not move or operate unit
where it could tip.
!
Do not use this equipment to sup-
port personnel, large tools, or
other material.
!
Special installation may be re-
quired where gasoline or volatile
liquids are present
ticle 511 or CEC Section 20.
Moving The Equipment
1
Lifting Forks
1
2
Locking Casters
1 Lifting Forks
Use wheels or lifting forks to move unit.
2 Locking Casters
If using lifting forks, extend forks beyond
opposite side of unit.
Use wheels or lifting forks to move unit.
Power Supply
If using lifting forks, extend forks beyond op-
3
115 Volt, 20 Amp AC Grounded
posite side of unit.
Receptacle
4
Input Power Cord
3 115
Receptacle
3
A 115 volt AC, 20 amp individual branch
circuit protected by time delay (type D)
4 Input Power Cord
fuses or circuit breaker is required.
A 115 volt AC, 20 amp individual branch cir-
Position unit near the welding operation
and close to compressed air supply and
cuit protected by time delay (type D) fuses or
circuit breaker is required.
115 volt AC receptacle. Keep unit away
from obstructions that may restrict
Position unit near the welding operation and
movement of the fume collector or ex-
close to compressed air supply and 115 volt
tension arm.
AC receptacle. Keep unit away from obstruc-
tions that may restrict movement of the fume
collector or extension arm.
Ref. LocFiltair_Mobile1 2018-08
Only qualified persons should in-
stall, operate, maintain, and repair
have
this unit.
Installation must meet all National,
State, and Local Codes - have only
qualified
persons
make
installation.
Do not move or operate unit where
it could tip.
Do not use this equipment to sup-
port personnel, large tools, or oth-
er material.
see NEC Ar-
Special installation may be re-
quired where gasoline or volatile
liquids are present - see NEC Ar-
ticle 511 or CEC Section 20.
Volt,
20
Amp
AC
Grounded
800402-A / 805268
OM-239025 Page 17