Replacing The Vs-2400Cd's Battery - Roland VS-2400CD Mode D'emploi

Poste de travail de studio numérique
Table des Matières

Publicité

Connecting an MB-24 Level Meter
1. With the power to the VS-2400CD and the MB24 turned off, connect the
VS-2400CD's MIDI OUT to the MB-24's MIDI IN using a MIDI cable.
2. If you want to connect another MIDI device to the VS-2400CD, connect its input to
the MB-24's MIDI THRU jack using a MIDI cable.
3. Turn on the power to your devices.
When using the MB-24, set the VS-2400CD's MIDI OUT/THRU parameter to Out
(Page 286). To learn how to configure the meter bridge, see the "EXTERNAL LEVEL
METER" parameter section on Page 352.

Replacing the VS-2400CD's Battery

The VS-2400CD contains a lithium battery that powers its time-keeping features, and
also provides the power for the area of the VS-2400CD's memory that stores certain
parameter values. When the battery weakens, the VS-2400CD's time-keeping features
may not operate correctly, and it may not properly remember various settings upon
power-up. If the battery needs to be replaced, the VS-2400CD shows the following
message when you power up:
Use only the specified type (model no. CR2032) of lithium battery. Be sure to insert it as
directed (to ensure correct polarity).
Before turning the VS-2400CD upside-down to install a new battery, obtain some
newspapers or magazines and place them under the four corners of the VS-2400CD, or
at both ends, to prevent damage to the buttons and controls. Position the VS-2400CD
carefully to avoid scratching or damaging it.
When installing a new battery, follow the precautions listed on page 375.
Installation Procedure
1. Power down the VS-2400CD (Page 78), saving any recent changes you've made to
the currently loaded project.
2. Turn off all connected devices, and disconnect all cables from VS-2400CD.