Télécharger Imprimer la page

Könner & Söhnen KS 2100i S Mode D'emploi page 21

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 28
CHECKING THE OIL LEVEL
CHECKING THE OIL LEVEL
The generator is transported free of motor oil. Do not start the engine until it is filled with sufficient amount of motor oil.
1. Unscrew the oil dipstick and wipe it out with a clean cloth.
2. Insert the dipstick without screwing it in.
3. Check the oil level by a mark on the oil dipstick.
4. Add oil if its level is below the mark on the oil dipstick.
5. Screw on the dipstick.
Recommended motor oil: SAE 10W30, SAE 10W40.
Recommended motor oil:
Recommended motor oil grade: API Service SG type or higher.
Recommended motor oil grade:
Motor oil quantity: see specifications table.
Motor oil quantity:
Before starting the engine, make sure that the rated power of power consumers matches with the power of generator. Do not exceed the
Before starting the engine,
nominal power of the generator. Do not connect any devices before you start the engine!
IMPORTANT!
ATTENTION – DANGER!
COMMISSIONING
COMMISSIONING
IMPORTANT!
1. Fill the crankcase with engine oil. The recommended amount of oil for each model is indicated in the specification chart.
2. Check oil level with an oil dipstick. It should be between the MIN and MAX marks on the oil dipstick.
3. Check fuel level.
4. Check the air filter for correct installation
IN THE FIRST 20 OPERATING HOURS OF THE GENERATOR, THE FOLLOWING REQUIREMENTS SHOULD BE MET:
IN THE FIRST 20 OPERATING HOURS OF THE GENERATOR, THE FOLLOWING REQUIREMENTS SHOULD BE MET:
1. During commissioning, do not connect power consumers, the power of which exceeds 50% of the nominal (operating) power of the
device.
2. After the first 20 operating hours, be sure to change the oil. It is better to drain oil while the engine is still hot after operation to ensure
quick and complete oil draining.
3. Check and clean the air filter, fuel filter and spark plug.
ENGINE START
ENGINE START
IMPORTANT!
IMPORTANT!
IMPORTANT!
FOR MODELS KS 2100i i S, KS 3100
FOR MODELS KS 2100
S, KS 3100i S i S
1. Check oil level.
2. Check fuel level.
3. Open the vent on the fuel cap to the "ON" position (fig. 1).
4.Turn the Multifunctional engine switch to the "START" position (fig. 2).
Do not connect any devices before you start the engine!
Do not change the controller settings in terms of the amount of
fuel or speed governor (this adjustment was made at the factory).
Otherwise, this may result in changes in the engine operation or its
failure.
In the power supply mode, the generator should operate no longer
than 1 minute in the range from nominal to maximum power.
The generator is supplied with disconnected battery. When using the
generator for the first time, open the maintenance door and connect
the battery line. For long-term storage of generator, disconnect the
battery line. (for models KS 5500iES ATSR, KS 5500iEG S).
Useful tip: If the engine stalls or does not start, turn the engine switch
to the "START"(ON) position, and then pull the manual starter. If the
oil level indicator flickers for several seconds, add oil and restart the
engine.
Each time you start the generator, be sure to check oil and fuel level
Before starting the generator, connect the ground wire to the ground
terminal.
GETTING STARTED
www.ks-power.de/en
FILL TO HERE
FILL TO HERE
7
| 20

Publicité

loading

Ce manuel est également adapté pour:

Ks 2100ig sKs 3100i sKs 3100ig sKs 5500ies atsrKs 5500ieg s