OIL LEVEL INDICATOR
OIL LEVEL INDICATOR
When the oil level falls below the level required for operation, the oil level indicator lights up, and then the engine stops automatically.
The engine will not start until oil is added.
AC INDICATOR
AC INDICATOR
When the generator is running and producing electricity, the AC indicator light is on.
DC FUSE
DC FUSE
The DC protector automatically switches to "OFF" when the current of the operating electrical device is higher than the rated current. To
use this equipment again, turn on the DC fuse again by pressing the "ON" button.
IMPORTANT!
OVERLOAD INDICATOR
OVERLOAD INDICATOR
The overload indicator lights up when the connected generator is overloaded, the inverter control unit overheats or the AC output voltage
rises.
If the overload indicator goes on, the engine will continue to operate, but the generator will no longer produce electricity. In this case,
you must perform the following steps:
1. Turn off all connected electrical appliances and stop the engine.
2. Reduce the total power of the connected devices until the nominal power of the generator is reached.
3. Check if the vent grid is clogged. Remove excess dirt or debris, if any.
4. After checking, start the engine.
IMPORTANT!
FUEL INDICATOR (FOR DUAL-FUEL GENERATORS)
FUEL INDICATOR (FOR DUAL-FUEL GENERATORS)
The indicator shows the type of fuel used to run the generator: green for LPG and blue for gasoline.
FUEL TANK CAP AIR VENT (EXPECT FOR MODELS KS 5500
FUEL TANK CAP AIR VENT (EXPECT FOR MODELS KS 5500i i ES ATSR, KS 5500
The fuel cap is equipped with a vent for air supply to the fuel tank. When the engine is running on gasoline,
the vent must be in the "ON" position (OPEN). This will allow fuel to enter the carburetor for engine
operation. After the generator stops, allow it to cool down and close the air vent on the fuel cap. When the
generator is not in use, close the vent to the "OFF" position.
EARTHING BOLT
EARTHING BOLT
In all cases, except for an IT system with an insulated neutral wire and bonding, the generator earthing bolt
must be connected to the grounding circuit with a flexible copper conductor with a cross-sectional area of
at least 6 mm
.
2
CHECKING THE FUEL LEVEL
CHECKING THE FUEL LEVEL
1. Unscrew the fuel cap and check the fuel level in the tank.
2. Fill the fuel tank to the fuel filter level.
3. Tighten the fuel cap securely.
4. For silent models of inverter generator, open the air intake vent on the fuel cap.
Recommended fuel:
Recommended fuel: unleaded fuel.
Fuel tank volume:
Fuel tank volume: see specifications table.
IMPORTANT!
IMPORTANT!
If the DC fuse turns off, reduce the load of the connected electrical
device. If the DC protector turns off again, stop operation and contact
your nearest Könner & Söhnen service center.
The overload indicator may light up within several seconds after start-
up or when connecting electrical devices requiring a high starting cur-
rent, such as a compressor or voltage indicator. However, this is not
a malfunction.
ES ATSR, KS 5500i i EG S)
CHECK BEFORE GETTING STARTED ON GASOLINE
Wipe up spilled fuel immediately with a clean, dry, soft cloth, as the
fuel may harm painted surfaces or plastic parts.
Use only unleaded gasoline. Using leaded gasoline can cause serious
damage to the inside of the engine.
GENERATOR OPERATION
EG S)
www.ks-power.de/en
5
6
| 19