Model
Voltage, V
Maximum power, kW
Nominal power, kW
Frequency, Hz
Current, A (max.)
Outlets
Engine start
Fuel tank volume, l
LED display
Noise level Lpa (7m)/Lwa, dB
Output 12V, A
USB-Outputs
Engine model
Engine volume, cm
3
Engine type
Engine power, hp
Generator parallel socket
Crankcase volume, l
Power factor, cos φ
ATS input
Dimensions (L*W*H), mm
Lithium battery, Ah
Net weight, kg
Protection class
*LPG operation reduces generator power by 10%.
**Multifunctional LED-display: voltage, frequency, working hours; overload indicator, voltage indicator, oil level indicator. To ensure reliability and in-
crease the engine service life, peak powers may be slightly limited by circuit breakers.
The optimal operating conditions are ambient temperature of 17-25°C, barometric pressure of 0.1 MPa (760 mm Hg), and relative humidity of 50-60%.
Under these environmental conditions, the generator can provide maximum performance in terms of the declared specifications. In the event of devia-
tions from these environmental indicators, the generator performance may vary.
Please note that continuous loads exceeding 80% of the generator's rated power are not recommended in order to extend its service life.
It is recommended to ground the generator before operating it for the first time. Before starting the device, remember that the total power of the
connected power consumers should not exceed the nominal power of the generator.
IMPORTANT!
KS 2100i S
KS 2100iG S
2.0
2.0*
1.8
1.8*
8.7
8.7
1*16A
1*16A
manual
manual
4.0
4.0
voltage, frequency, working hours
62/87
62/87
12V/8.3A
12V/8.3A
5V/1A, 5V/2,1A
5V/1A, 5V/2,1A
KS 110i
KS 110i
79.7
79.7
LPG/gasoline
gasoline, 4 stroke
4 stroke cycle
cycle engine
engine
3.3
3.3
+
+
0.35
0.35
1
1
-
-
510*320*475
510*320*475
-
-
18.5
19
Nominal voltage tolerance – max. 5%
TERMS OF USE OF INVERTER GENERATOR
Make sure that the control panel, the blinds and the underside of the inverter are
well cooled and protected against the ingress of small solids, dirt, and water. Im-
proper operation of the cooler can cause damage to the motor, inverter or alter-
nator.
SPECIFICATIONS
KS 3100i S
KS 3100iG S
230
3.1
3.1*
2.8
2.8*
50
13.5
13.5
1*16A
1*16A
manual
manual
4.0
4.0
63/88
63/88
12V/8.3A
12V/8.3A
5V/1A, 5V/2,1A
5V/1A, 5V/2,1A
KS 160i
KS 160i
145
145
LPG/gasoline
gasoline, 4 stroke
4 stroke cycle
cycle engine
engine
4.6
4.6
+
+
0.45
0.45
1
1
-
-
510*320*475
510*320*475
-
-
21.5
22
IP23M
KS 5500iES ATSR KS 5500iEG S
5.5
5.0
23.9
1*16А, 1*32А
1*16А, 1*32А
manual/electro
manual/electro
13.5
multifunctional**
66/91
12V/8.3A
12V/8.3A
5V/1A, 5V/2,1A
5V/1A, 5V/2,1A
KS 330i
KS 330i
312
LPG/gasoline
gasoline, 4 stroke
4 stroke cycle
cycle engine
engine
9.5
+
0.85
1
+
680*510*605
765*510*605
1.6
52
www.ks-power.de/en
3
5.5*
5.0*
23.9
13.5
66/91
312
9.5
+
0.85
1
-
1.6
52.5
4
| 18