Technical Data - Berkel BV 400/25 Mode D'emploi

Conditionneuses sous vide a cloche
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

PROBleM
Poor sealing.
gas quantity in bags insufficient. • Gas flushing time insufficient.
lid opens during gaS cycle.

TECHNICal daTa

WEIGHT
DIMENSIONS
ELECTRIC CONNECTION
CHAMBER SIZE
LENGTH OF SEAL
PUMP POWER
MAXIMUM POWER ABSORPTION
FUSES
OIL TYPE
OIL CHARGE
OIL CHANGE FREQUENCY (PUMP WORKING
HOURS)
ENVIRIONMENTAL OPERATING
CONDITIONS
HUMIDITY IN ENVIRONMENT OF USE
NOISE LEVEL
Instruction manual for vacuum chamber packaging machines Mod. BV 400/25 – BV 400/25H – BV 600/60
Instruction manual for vacuum chamber packaging machines Mod. BV 400/25 - BV 600/60
Rev. 01 - 04/2019 - Cod. 1500656 - Instruction manual for vacuum chamber packaging machines Mod. C46-C46H-C62
POSSIBle CaUSeS
• Sealing bar dirty.
• Sealing time insufficient for basic
bag weight.
• Teflon cover worn.
• Pressure bar silicon strip worn.
• Gas cylinder pressure Insuffi-
cient.
• Gas nozzle not inserted in bag
mouth.
• Cylinder valve or pressure redu-
cer closed.
• Gas percentage too high.
8. TeChNICal DaTa
BV 400/25
C46
kg
96
mm
600×710×500h
B mm
710
H mm
500
V - Hz
230 - 50/60
mm
485×550×175h
1B
455
mm
2BL
2×520
mm
2BC
2×455
mm
m
3
/h
25
W
1200
PF1
10A
PF2
5 - 10A
PF4
4A
ORV60 ISO VG68
DIN 51524/3 (HVLP)
ISO 11158:1997 (HV)
1,2
200 pump
working hours
°C
12-40
%
10-80
dB
70
SoluTIoN
• Clean sealing bar.
• Increase sealing time.
• Change Teflon cover.
• Change the pressure bar silicon strip.
• Increase the gas injection time.
• Adjust pressure on cylinder reducer to 1 bar.
• Reposition bag by inserting gas nozzle in the
bag mouth.
• Open cylinder valves and adjust pressure
reducer to 1.0 bar.
• Reduce gas percentage.
ModElS
BV 400/25H
C46H
116
600×710×1035h
710
1035
230 - 50/60
400 (3p+PE) - 50/60
485×550×175h
455
2×520
2×455
25
1200
10A
5 - 10A
4A
ORV60 ISO VG68
DIN 51524/3 (HVLP)
DIN 51524/3 (HVLP)
ISO 11158:1997 (HV)
ISO 11158:1997 (HV)
1,2
200 pump
working hours
12-40
10-80
70
BV 600/60
C62
167
765×710×1050h
710
1050
650×535×200h
/
2×620
2×505
60
1500
1A
4 - 6A
5A
ORV60 ISO VG68
1,5
200 pump
working hours
12-40
10-80
37
70

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Bv 400/25hBv 600/60

Table des Matières