Instruction manual for vacuum chamber packaging machines Mod. BV 400/25 - BV 600/60
Instruction manual for vacuum chamber packaging machines Mod. BV 400/25 – BV 400/25H – BV 600/60
Rev. 01 - 04/2019 - Cod. 1500656 - Instruction manual for vacuum chamber packaging machines Mod. C46-C46H-C62
aTTENTIoN! Stop the machine immediately if there is gas leakage caused by defective or rusty
unions or damaged pipes.
Contact your nearest Service Centre for replacement of damaged parts.
warNINg! To avoid increase in oil density which could affect regular
working of the pump, make sure that the environmental temperature
never falls below 10°C.
warNINg! The pump oil must be checked every time the machine is used
through the level glass provided on the side of the machine's rear panel.
The oil level must be between the MINIMuM and MaXIMuM level.
The oil must be golden coloured and clear.
WaRNINg! The PUMP OIl MUST Be ChaNgeD PeRIODICally; The OIl ChaNge FReqUeNCy
MUST Be INCReaSeD PROPORTIONally TO The WORKlOaD TO WhICh The MaChINe IS
SUBJeCTeD. The OIl MUST Be ChaNgeD eveRy 25.000 CyCleS (CORReSPONDINg TO
aPProX. 200 HourS of oPEraTIoN). for EaCH oIl CHaNgE, IT IS NECESSary To rE-
PlaCE THE EXHauST fIlTEr: for 60 m
The oil and filter change frequency increases if liquids or wet products are handled; in such cases, the
oil must be changed if the machine has remained unused for a month or a longer period.
Before an inactivity period of two months or longer, the oil must be changed.
a whitish and cloudy or dark and transparent oil means suction of liquids and moisture, or that the oil
is old, respectively.
Digitally controlled models are equipped with an oil change signaling system: once the maximum limit
of work cycles has been reached, an "oil alarm" warning appears on the display each time the machine
is started and at the end of each cycle. The number of cycles already completed can be called up on
the display at any time using the relative keys on the control panel.
Periodically perform an oil dehumidification cycle (for detailed informations see chap. 5.3).
18
/h PuMP CHaNgE alSo THE oIl fIlTEr.
3