7.3.7 CHaNgINg THE PuMP EXHauST fIlTEr

warNINg!
This operation must be carried out by qualified personnel.
• Remove the stainless steel panel on the rear of the machine.
• 25 m
/h pumps: unscrew plug
3
• 60 m
/h pumps: unscrew the 4 screws
3
• Remove filter
from its seat.
C
• Insert the new filter after checking to make sure O-ring
• Refit the cover by fixing spring
7.3.8 ChaNgINg The lID gaSKeT aND The PReSSURe BaR SIlICON STRIP
• Open the plexiglas cover.
• Remove cover gasket
• Insert the new gasket or the pressure bar silicon strip, pushing it deep into the cavity all the way.
• Run a loadless cycle so that the gasket or the pressure bar silicon strip fits in its seat.
Instruction manual for vacuum chamber packaging machines Mod. BV 400/25 – BV 400/25H – BV 600/60
Rev. 01 - 04/2019 - Cod. 1500656 - Instruction manual for vacuum chamber packaging machines Mod. C46-C46H-C62
on the pump body using pliers.
a
B
from the filter cover.
on the filter projection
E
a
B
or the pressure bar silicon strip
g
g
Instruction manual for vacuum chamber packaging machines Mod. BV 400/25 - BV 600/60
Instruction manual for vacuum chamber packaging machines Mod. BV 400/25 - BV 600/60
is in the correct position.
d
f
.
f
E
B
and clean the seats to remove dirt.
H
C
d
H
33