the dedicated control from item RF on the TECHNICAL ASSISTANCE MENU. The fault log cannot be deleted with a manual reset, by switching
off the appliance, or by resetting the factory values, unless the procedure described above has been followed.
5.2 - Monitor Menu
From the main menu, by holding down simultaneously for 2 sec the keys "SET" and "˅" (minus), or using the selection menu and pressing ˄ or
˅, you can access the MONITOR MENU. In this menu, by pressing the MODE key, the following values are displayed in sequence.
5.2.1 - CT: Display contrast
Parameter not available on pumps with firmware version 3.xx. Adjusts the display contrast.
5.2.2 - BK: Display brightness
Adjusts the backlighting of the display on a scale from 0 to 100.
5.2.3 - TK: Backlight switch-on time
Sets the time that the backlight is lit since the last time a key was pressed. Values allowed: 20 sec to 10 min or always on (even if this option is
selected, the screen will still go into standby mode after a few hours of inactivity to safeguard the integrity of the device). When the backlight is
off, the first time any key is pressed has the sole effect of restoring the backlighting.
5.2.4 - LA: Language
Display in one of the following languages:
• Italian
• English
• French
• German
5.2.5 - TE: Dissipator temperature display
5.3 - Setpoint Menu
From the main menu, hold down simultaneously the "MODE" and "SET" keys until "SP" appears on the display (or use the selection menu pressing
˄ or ˅). The ˄ and ˅ keys allow you respectively to increase and decrease the plant boosting pressure.
Press SET to leave this menu and return to the main menu. The range of adjustment is 1-5.5 bar (14-80 psi).
5.3.1 - SP: Setting the setpoint pressure
Pressure at which the system is pressurised.
The pump restarting pressure is linked not only to the set pressure SP but also to RP. RP expresses the decrease in pressure,
with respect to "SP" caused by the pump starting.
For example: SP = 3,0 [bar]; RP = 0,3 [bar];
During normal operation the system is pressurised at 3.0 [bar].
The electropump restarts when the pressure falls belowai 2,7 [bar].
Setting a pressure (SP) that is too high for the pump performance may cause false water lack errors BL; in these cases lower
the set pressure.
5.4 - Manual Menu
In manual operation, the sum of the input pressure and the maximum pressure that can be supplied must not be greater than 6
bar.
From the main menu, hold down simultaneously the "SET" and "˄" and "˅" keys until the manual menu page appears (or use the selection menu
pressing ˄ or ˅). Press SET to leave this menu and return to the main menu. Entering the manual menu by pressing the SET ˄ ˅ keys puts the
machine into forced STOP condition. This function can be used to force the machine to stop. In the main menu, irrespective of the parameter
displayed, it is always possible to perform the following controls:
Temporary starting of the electropump.
Pressing the MODE and ˄ keys at the same time causes the pump to start at speed RI and this running status remains as long as the two keys
are held down. When the pump ON of pump OFF command is given, a communication appears on the display.
Starting the pump
Holding down the MODE ˅ ˄ keys simultaneously for 2 sec. causes the pump to start at speed RI. The running status remains until the SET key
is pressed. The next time the SET key is pressed the pump leaves the manual menu. When the pump ON of pump OFF command is given, a
communication appears on the display. In case of operation in this mode for more than 5' with no flow of liquid, an alarm overheating alarm will