Monitor Menu; Setpoint Menu - DAB esybox max 85/120 Instructions Pour L'installation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 73
8.1.6 NT: Display of network configurations
Information on network and serial connections for connectivity. The serial for connectivity can be displayed in full by pressing the "^" key.
8.1.7 VE: Version display
Information on the hardware version, serial number and mac address of the pump.
For firmware versions 5.9.0 and later, the following also applies: on this page after the prefix S: the last 5 figures of the single serial number
attributed for connectivity are used. The whole serial number can be viewed by pressing the "^". key.
8.1.8 FF: Fault log display (log)
Chronological display of the faults that have occurred during system operation.
Under the symbol FF appear two numbers x/y indicating respectively the fault displayed and the total number of faults present; to the right of
these numbers is an indication of the type of fault displayed. The ^ and ˅ keys scroll through the list of faults: pressing the ˅ key goes back
through the log and stops at the oldest fault present, pressing the ^ key goes forward in the log and stops at the most recent fault.
The faults are displayed in chronological order from the one that appeared furthest back in time x=1 to the most recent one x=y. The date and
time when the fault occurred is also displayed for each one. The maximum number of faults that can be displayed is 8; when this number is
reached, the list starts to overwrite the oldest ones.
This menu item displays the list of faults, but does not allow resetting. Reset can be carried out only with the dedicated control from item RF on
the TECHNICAL ASSISTANCE MENU.
The fault log cannot be deleted with a manual reset, by switching off the appliance, or by resetting the factory values, unless the procedure
described above has been followed.

8.2 Monitor Menu

From the main menu, by holding down simultaneously for 2 sec the keys "SET" and "˅ ",or using the selection menu and pressing ^ or ˅ , you
can access the MONITOR MENU. In this menu, by pressing the MODE key, the following values are displayed in sequence.
8.2.1
BK: Display brightness
Adjusts the backlighting of the display on a scale from 0 to 100.
8.2.2
TK: Backlight switch-on time
Sets the time that the backlight is lit since the last time a key was pressed. Values allowed: '0' always off; from 20 sec to 10 min or 'always on'.
When the backlight is off, the first time any key is pressed has the sole effect of restoring the backlighting.
8.2.3
LA: Language
Display in one of the following languages:
• Italian
• English
• French
• German
• Spanish
• Dutch
• Swedish
• Turkish
• Slovak
• Romanian
• Russian
• Thai
• Portuguese
8.2.4
TE: Heat sink temperature display

8.3 Setpoint Menu

From the main menu, hold down simultaneously the "MODE" and "SET" keys until "SP" appears on the display (or use the selection menu
pressing ^ or ˅ ).
The ^ and keys allow you respectively to increase and decrease the plant boosting pressure.
Press SET to leave this menu and return to the main menu.
8.3.1
SP: Setting the setpoint pressure
Pressure at which the system is pressurised: min 1.0 bar (14 psi) - max 12.0 bar (174 psi)