multipin m12 cable plug (not
supplied)
- Loosen threaded ring [1]
- Remove part [2] from the cable plug
- Wire acc. to pin assignment (see 4.3.2).
8311
4.3 electrical connection
Always ensure the power supply is switched off before working on the
device. All the cable plugs must be plugged out. Use:
- a shielded cable with an operating temperature > +80 °C.
- a high quality voltage supply (filtered and regulated).
- install a properly dimensioned fuse for the power supply.
- connect the shielding to the earth, at both ends of the cable,
using a connection as short as possible.
4.3.1 cable plugs
208 cable plug (supplied)
- To open the plug, unfasten screw [1]
- Remove part [3] from part [2].
- Unscrew cable gland [5].
- Insert cable into part [2] via cable gland.
- Wire part [3] (see 4.3.3).
- Replace part [3] into part [2], by 90°-steps.
- Tighten cable gland [5]. Place gasket [4] between the cable plug and
the fixed connector of the transmitter and plug the 2508 onto the fixed
connector.
- Tighten screw [1] to ensure tightness and correct electrical contact.