Burkert 8311 Manuel D'installation page 33

Masquer les pouces Voir aussi pour 8311:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

to adjust the 4-20 mA
output of the transmitter:
- Select feature OFFS: the
transmitter generates a 4 mA
output current; Measure the
current at the 4-20 mA output
using a multimeter, enter
the measured value into the
OFFS feature.
- Select feature SPAN:
the transmitter generates
a 20 mA output current;
Measure the current at the
4-20 mA output using a mul-
timeter, enter the measured
value into the SPAN feature.
to choose to go back or not
to the default configuration
of the Calibration and/or
Test modes (see pages 31
and 34).
to return to the display of
the pressure in the Normal
mode, with (SAVE YES) or
without (SAVE NO) saving
the settings made.
8311
0......9
ENTER
CAL
1)
TEST
3.95
ENTER
ENTER
ma
OFFS ma
0......9
*
NO
TEST
ENTER
ENTER
RSET
RSET
0......9
CAL
ENTER
RSET
TEST
ENTER
RSET
TEST
NO
ENTER
ENTER
END
SAVE
0......9
YES
ENTER
SAVE
* To move the decimal point, press simultaneously keys
33
10.00
9.985
ENTER
ENTER
UNIT
TEACH KFAC
2)
0......9
*
20.50
ENTER
SPAN ma
0......9
*
Back to normal mode (see
1
p.21)
% KFAC < 20% ?
01.00
ENTER
&
% KFAC > -20% ?
% KFAC
and
0......9

Publicité

Table des Matières
loading