Specifications – SubDrive30/SubDrive50
NEMA 3R
Model No.
(indoor/outdoor)
Voltage
Phase In
Frequency
Current (max)
Input from
Power Factor
Power Source
Power (idle)*
Power (max)
Wire Gauge Size(s)
Voltage
Phase Out
Output to
Frequency Range
Motor
Current (max)
Wire Gauge Size(s)
Factory Preset
Pressure
Setting
Adjustment Range
Temperature
Operating
(at 230 VAC input)
Conditions
(A)
Relative Humidity
Controller Size
(B)
NEMA 3R
(approximate)
Pump (60 Hz)
For Use With
FE Motor
Notes:
(A) Operating temperature is specified at full output power when installed as described in Location of Drive on pg. 10-14.
(B) Refer to pg. 23-26 for detailed Drive Mounting.
(C) When a SubDrive30/SubDrive50 is used with a single-phase 3-wire motor (see Motor Type on pg. 28), the MonoDrive pump and
motor specifications on page 37 apply.
* Idle power is defined as input power used by the drive when the drive is not running the motor, the drive fan is off, and no
communication is active. Idle power is increased by 1 W if Wi-Fi is on.
SubDrive30
5870205403C
208/230 +/- 10% VAC
Single-Phase
60/50 Hz
23 A
~ 0.95
5 W
4.2 kW
See Table 1, pg. 18. Consult Federal, State, and Local
codes for branch circuit installations
Variable based on frequency
Single-Phase (3-Wire) OR Three-Phase
30-78 Hz (1.5 hp, 1.1 kW) pump
30-70 Hz (2 hp, 1.5 kW) pump
30-60 Hz (3 hp, 2.2 kW) pump
30-63 Hz (Single-Phase Motors)
10.9 A (three-phase), 13.2 A (single-phase)
See Table 2, pg. 19 for wire sizing
50 psi (3.4 bar)
Analog Transducer: 5-95 PSI (0.3 - 6.6 bar)
Pressure Sensor: 25-80 psi (1.7 - 5.5 bar)
-13 °F to 122 °F (-25 °C to 50 °C)
20-95%, non-condensing
9 3/4" x 19 3/4" x 5 1/4" : 26 lbs
(25 x 50 x 13 cm) : (11.8 kg)
0.5 hp (0.37 kW) pump with 214505-series motor
0.75 hp (0.55 kW) pump with 214507-series motor
1.0 hp (0.75 kW) pump with 214508-series motor
1.5 hp (1.1 kW) pump with 224300-series motor
2.0 hp (1.5 kW) pump with 224301-series motor
0.5 hp (0.37 kW), 0.75 hp (0.55 kW), or 1.0 hp (0.75 kW)
pump with 234513-series motor
0.75 hp (0.55 kW), 1.0 hp (0.75 kW), or 1.5 hp (1.1 kW)
pump with 234514-series motor
1.0 hp (0.75 kW), 1.5 hp (1.1 kW), or 2.0 hp (1.5 kW) pump
with 234315-series motor
1.5 hp (1.1 kW), 2.0 hp (1.5 kW), or 3.0 hp (2.2 kW) pump
with 234316-series motor
214505- series (0.5 hp, 0.37 kW) single-phase, 3-wire
214507- series (0.75 hp, 0.55 kW) single-phase, 3-wire
214508-series (1.0 hp, 0.75 kW) single-phase, 3-wire
224300-series (1.5 hp, 1.1 kW) single-phase, 3-wire
224301-series (2.0 hp, 1.5 kW) single-phase, 3-wire
234513- series (1.0 hp, 0.75 kW) three-phase
234514-series (1.5 hp, 1.1 kW) three-phase
234315-series (2.0 hp, 1.5 kW) three-phase
234316-series (3.0 hp, 2.2 kW) three-phase
SubDrive/MonoDrive Connect
SubDrive50
5870205503C
208/230 +/- 10% VAC
Single-Phase
60/50 Hz
36 A
~ 0.95
7 W
7.2 kW
See Table 1, pg. 18. Consult Federal, State, and Local
codes for branch circuit installations.
Variable based on frequency
Single-Phase (3-wire) OR Three-Phase
30-78 Hz: 1/2-rated mismatched pump with three-phase
motor
30-70 Hz: 2/3 or 3/4-rated mismatched pump with three-
phase motor
30-60 Hz: Matched pump with three-phase motor
30-63 Hz: Matched pump with single-phase motor
17.8 (three-phase), 17.0 A (single-phase)
See Table 2, pg. 19 for wire sizing
50 psi (3.4 bar)
Analog Transducer: 5-95 PSI (0.3 - 6.6 bar)
Pressure Sensor: 25-80 psi (1.7 - 5.5 bar)
-13 °F to 122 °F (-25 °C to 50 °C)
20-95%, non-condensing
26 1/8" x 15 3/8" x 11 1/2" : 31 lbs
(66 x 39 x 29 cm) : (14.1 kg)
0.5 hp (0.37 kW) pump with 214505-series motor
0.75 hp (0.55 kW) pump with 214507-series motor
1.0 hp (0.75 kW) pump with 214508-series motor
1.5 hp (1.1 kW) pump with 224300-series motor
2.0 hp (1.5 kW) pump with 224301-series motor
3.0 hp (2.2 kW) pump with 224302-series motor
0.5 hp (0.37 kW), 0.75 hp (0.55 kW), or 1.0 hp (0.75 kW)
pump with 234513-series motor
0.75 hp (0.55 kW), 1.0 hp (0.75 kW), or 1.5 hp (1.1 kW)
pump with 234514-series motor
1.0 hp (0.75 kW), 1.5hp (1.1 kW), or 2.0 hp (1.5 kW) pump
with 234315-series motor
1.5 hp (1.1 kW), 2.0 hp (1.5 kW), or 3.0 hp (2.2 kW) pump
with 234316-series motor
3.0 hp (2.2 kW), or 5.0 hp (3.7 kW) pump with
234317-series motor
214505-series (0.5 hp, 0.37 kW) single-phase, 3-wire
214507-series (0.75 hp, 0.55 kW) single-phase, 3-wire
214508-series (1.0 hp, 0.75 kW) single-phase, 3-wire
224300-series (1.5 hp, 1.1 kW) single-phase, 3-wire
224301-series (2.0 hp, 01.5 kW) single-phase, 3-wire
224302-series (3.0 hp, 2.2 kW) single-phase, 3-wire
234513-series (1.0 hp, 0.75 kW) three-phase
234514-series (1.5 hp, 1.1 kW) three-phase
234315-series (2.0 hp, 01.5 kW) three-phase
234316-series (3.0 hp, 2.2 kW) three-phase
234317-series (5.0 hp, 3.7 kW) three-phase
39