Specifications; Monodrive Connect/Monodrive Xt Connect - Franklin Electric SubDrive 15 Manuel Du Propriétaire

Masquer les pouces Voir aussi pour SubDrive 15:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

SPECIFICATIONS

MonoDrive Connect/MonoDrive XT Connect

NEMA 3R
Model
(indoor/outdoor)
Voltage
Phase In
Frequency
Current (max)
Input from
Power Source
Power Factor
Power (idle)
Power (max)
Wire Gauge Size(s)
Voltage
Phase Out
Frequency Range
Output to
Motor
Current (max)
Wire Gage Size(s)
Factory Preset
Pressure
Setting
Adjustment Range
Temperature
Operating
(at 230 VAC input)
Conditions*
Relative Humidity
Temperature
Storage**
Shelf Life
Dimensions
NEMA 3R
and Weight
* Operating temperature is specified at full output power when installed as recommended. Refer to
"Over Temperature Foldback" on page 34
** Shelf life can be extended for one year by powering the drive for 60 minutes with no load.
MonoDrive
5870205003C
208/230 ± 10% VAC
Single-Phase
60/50 Hz
5.7 Amps (RMS) 1/2 hp, 0.37 kW system
8.7 Amps (RMS) 3/4 hp, 0.55 kW system
11 Amps (RMS) 1 hp, 0.75 kW system
~ 0.95
4 Watts
2.5 kW
Refer to
"Fuse/Circuit Breaker and Wire Sizing" on
page
20.
230 VAC Maximum
Single-Phase (3-Wire)
30 – 63 Hz
Main Phase: 6 Amps (RMS) 1/2 hp, 0.37 kW system
Main Phase: 8 Amps (RMS) 3/4 hp, 0.55 kW system
Main Phase: 10.4 Amps (RMS) 1 hp, 0.75 kW system
Refer to
"Maximum Motor Cable Length" on
page
21.
50 psi (3.4 bar)
Transducer: 5-95 psi (0.3-6.6 bar)
Pressure Sensor: 25-80 psi (1.7-5.5 bar)
–13 °F to 122 °F (–25 °C to 50 °C)
20-95%, non-condensing
–13 °F to 149 °F (–25 °C to 65 °C)
1.5 Years
9-3/4" x 16-3/4" x 5-1/4" : 20 lbs
(25 x 42.5 x 13 cm) : (9 kg)
.
MonoDrive Connect/MonoDrive XT Connect
MonoDrive XT
5870205203C
208/230 ± 10% VAC
Single-Phase
60/50 Hz
13 Amps (RMS) 1.5 hp, 1.1 kW system
16 Amps (RMS) 2 hp, 1.5 kW system
~ 0.95
5 Watts
4.2 kW
Refer to
"Fuse/Circuit Breaker and Wire Sizing" on
page
20.
230 VAC Maximum
Single-Phase (3-Wire)
30 – 63 Hz
Main Phase: 11.5 Amps (RMS) 1.5 hp, 1.1 kW system
Main Phase: 13.2 Amps (RMS) 2 hp, 1.5 kW system
Refer to
"Maximum Motor Cable Length" on
page
21.
50 psi (3.4 bar)
Transducer: 5-95 psi (0.3-6.6 bar)
Pressure Sensor: 25-80 psi (1.7-5.5 bar)
–13 °F to 122 °F (–25 °C to 50 °C)
20-95%, non-condensing
–13 °F to 149 °F (–25 °C to 65 °C)
1.5 Years
9-3/4" x 19-3/4" x 5-1/4" : 26 lbs
(25 x 50 x 13 cm) : (11.8 kg)
SPECIFICATIONS
51

Publicité

Table des Matières
loading

Table des Matières