Franklin Electric A Serie Manuel Du Propriétaire
Franklin Electric A Serie Manuel Du Propriétaire

Franklin Electric A Serie Manuel Du Propriétaire

Masquer les pouces Voir aussi pour A Serie:

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

BEFORE INSTALLING PUMP, BE SURE TO READ THIS
OWNER'S MANUAL CAREFULLY.
REFER TO PRODUCT DATA PLATE(S) FOR ADDITIONAL
OPERATING INSTRUCTIONS AND SPECIFICATIONS.
C A U T I O N
Do not run mechanical shaft seals dry. Fill
pump with water before starting or pump will be damaged.
The motor on this pump is guaranteed by the manufacturer
and in event of failure it must be returned to an authorized
service station for repairs. Motor warranty is void if repairs
aren't made by an authorized repair station.
Most water system troubles result from improper installation. We
therefore suggest that you read this manual carefully before starting
your pump. The "SERVICE CHECK LIST" will assist you in locating
and eliminating the cause of any trouble you may encounter later.
Check and make available all the tools you will need to install your
pump. These are wrenches, pipe sealant, pipe fittings and nipples,
screwdriver, etc. Be sure to have available the proper and adequate
wiring material.
INSPECT THE SHIPMENT
All pumps are carefully tested, crated and inspected to insure their
arrival in good condition. Occasionally, products may become
damaged during shipment.
When the pump is received, examine it closely to make sure there is
no damage or broken parts. If damage is evident, report immediately
to either the carrier who made the shipment or to the dealer from
which the pump was purchased. All pumps are water-tested prior to
shipment. If water film is found, it is the result of this testing.
READ AND FOLLOW
SAFETY INSTRUCTIONS
This is the safety alert symbol. When you see this symbol
on your pump or in this manual, look for one of the following
signal words and be alert to the potential for personal injury:
D A N G E R warns about hazards that will cause serious
personal injury, death or major property damage if ignored.
W A R N I N G warns about hazards that can cause serious
personal injury, death or major property damage if ignored.
A-SERIES PUMP
OWNER'S MANUAL
C A U T I O N warns about hazards that will or can cause minor
personal injury or major property damage if ignored.
The label NOTICE indicates special instructions, which are
important but not related to hazards.
Carefully read and follow all safety instructions in this manual
and on pump.
Keep safety labels in good condition.
Replace missing or damaged safety labels.
WA R N I N G
Hazardous voltage.
Can shock, burn, or
cause death.
Ground pump before
connecting to power
supply. Disconnect
power before working
on pump, motor
or tank.
IMPORTANT SAFETY
INSTRUCTIONS
When installing and using this electrical equipment, basic safety
precautions should always be follows, including the following:
READ AND FOLLOW
ALL INSTRUCTIONS
W A R N I N G To reduce the risk of injury, do not permit children to
use this product unless they are closely supervised at all times.
W A R N I N G Risk of Electric Shock. Connect only to a branch
circuit protected by a ground-fault circuit-interrupter (GFCI). Contact
a qualified electrician if you cannot verify that the circuit is protected
by a GFCI.
The unit must be connected only to a supply circuit that is protected
by a ground-fault circuit-interrupter (GFCI). Such a GFCI should be
provided by the installer and should be tested on a routine basis.
To test the GFCI, push the test button. The GFCI should interrupt
power. Push the reset button. Power should be restored. If the GFCI
fails to operate in this manner, the GFCI is defective. If the GFCI
interrupts power to the pump without the test button being pushed,
a ground current is flowing, indicating the possibility of an electric
shock. Do not use the pump. Disconnect the pump and have the
problem corrected by a qualified service representative before using.
C A U T I O N This pump is for use with permanently-installed
pools and may also be used with hot tubs and spas if so marked.
Wire motor for correct voltage.
See "Electrical" section of this
manual and motor nameplate.
Ground motor before connecting to
power supply.
Meet National Electrical Code,
Canadian Electrical Code, and local
codes for all wiring.
Follow wiring instructions in this
manual when connecting motor to
power lines.

Publicité

Table des Matières
loading

Sommaire des Matières pour Franklin Electric A Serie

  • Page 1 A-SERIES PUMP OWNER'S MANUAL C A U T I O N warns about hazards that will or can cause minor personal injury or major property damage if ignored. The label NOTICE indicates special instructions, which are important but not related to hazards. Carefully read and follow all safety instructions in this manual and on pump.
  • Page 2: Installation Location

    Do not use with storable pools. A permanently-installed pool is ELECTRICAL INSTRUCTIONS constructed in or on the ground or in a building such that it cannot If the unit is being installed for use with a swimming pool, spa, or hot be readily disassembled for storage.
  • Page 3: Pump Maintenance

    also important that the correct level of acidity or alkalinity of the SERVICE AND REPAIR PARTS pool water be maintained. This is measured in pH, a pH reading of Refer all service to your local dealer as his knowledge of your 7.0 is considered neutral.
  • Page 4 THIS WARRANTY SETS FORTH THE COMPANY’S SOLE OBLIGATION AND PURCHASER’S EXCLUSIVE REMEDY FOR DEFECTIVE PRODUCT. Franklin Electric Company, Inc. and its subsidiaries (hereafter “the Company”) warrants that the products accompanied by this warranty are free from defects in material or workmanship of the Company.
  • Page 5 POMPE A-SERIES MANUEL DU PROPRIÉTAIRE ATTENTION vous avertit d'un danger qui entrainera ou qui risque d'entrainer des blessures corporelles mineures ou des dommages matériels importants s'il est ignoré. La mention MISE EN GARDE introduit des instructions particulières qui sont importantes, mais ne sont pas liées aux risques. Veuillez lire attentivement et respecter toutes les consignes de sécurité...
  • Page 6: Lieu D'installation

    tourbillons et des spa si spécifié. Ne pas utiliser avec piscines pouvant être Nous recommandons l'utilisation d'un clapet anti-retour sur le tuyau remisées. Une piscine installée en permanence est construite dans ou sur d'aspiration au niveau de l'eau ou en dessous . le sol ou dans un bâtiment de telle sorte qu'elle ne peut être facilement INSTRUCTIONS ÉLECTRIQUES démontée pour être remisée.
  • Page 7: Dépannage

    PIÈCES D'ENTRETIEN ET DE RÉPARATION que le bon niveau d'acidité ou d'alcalinité de l'eau de piscine soit maintenu. Cela se mesure en pH, un pH de 7.0 est considéré comme neutre. La lecture Consultez votre revendeur local pour tout entretien car sa connaissance d'un pH supérieur à...
  • Page 8: Garantie Limitée

    CETTE GARANTIE ÉNONCE LA SEULE OBLIGATION DE L'ENTREPRISE ET LE RECOURS EXCLUSIF DE L'ACHETEUR POUR LE PRODUIT DÉFECTUEUX. Franklin Electric Company, Inc. et ses filiales (ci-après « la Société ») garantit que les produits accompagnés par cette garantie sont sans défauts de matière ou de fabrication de la Société.

Ce manuel est également adapté pour:

S2aS3aS35aS4aS45aS2at ... Afficher tout

Table des Matières