CAUTION
!
For retrofit application (i.e. MonoDrive), make sure to check integrity of power and motor leads.
This requires measuring the insulation resistance with the suitable megohmmeter.
* See AIM Manual for specifications.
6. Feed the 230 VAC power leads
through the larger opening on the
bottom left side of the SubDrive/
MonoDrive controller and connect
them to the terminals marked L1, L2,
and
.
Tighten terminals to 15 in-lbs
(1.7 Nm).
7. For analog pressure transducer
or pressure sensor leads, use the
smaller opening on the bottom of the
SubDrive/MonoDrive unit (to the right
of the input power leads).
For Analog Pressure Transducer
NOTE: A 10-foot (3 m) section of pressure transducer cable is provided with the controller.
Other lengths are available. See Accessories section for ordering information.
a. Locate the terminal block labeled
TRANSDUCER (XDCR).
b. Connect the RED lead of the pressure transducer cable to the +24 terminal of the
XDCR terminal block.
c. Connect the BLACK lead of the pressure transducer cable to the - terminal.
d. Connect the bare shield lead of the
pressure transducer cable to the S
terminal (where applicable).
e. Tighten terminals to 5 in-lbs (0.6 Nm) with
a small screwdriver (provided).
f. Torque the fitting as shown in the figure
to the right.
For SubDrive Pressure Sensor
s
CAUTION
!
When increasing the pressure, do not exceed the mechanical stop on the pressure sensor or 80
psi (5.5 bar). The pressure sensor may be damaged.
a. Locate the terminal block labeled PRESSURE SENSOR (PS).
b. Connect the red and black leads (interchangeable) of the pressure sensor cable to the
terminals of the PS terminal block on the Pressure Input Board.
SubDrive/MonoDrive Connect
Suitable for use on a circuit
capable of delivering not more
C2
than 5000 rms symmetrical
amperes, 250 V maximum. Use 75
ºC CU wire rate 300 V min.
R99
R104
C50
R100
Convenable pour utilisation sur un
C33
D15
circuit capable de livrer pas plus
R101
TP82
R103
C4
de 5000 ampères symétriques
R98
TP80
pae, 250 V maximum. Utilisez un fil
R105
nominale classifier 75 °C CU /
C49
D16
300 V min
R97
P1
Adecuado para utilizarse en un
IMAG
RoHS
94V-0
circuito capaz de entregar no más
Compliant
BD02
38 15
de 5.000 amperes RMS
simétricos, 250 V como máximo.
Use alambre de 75 °C CU con una
clasificación mínima de 300 V.
Tighten terminals to 15 in-lbs.
Serrer les terminaux à 15 po-lb
Apriete las terminales a
A
15 pulgadas-libra.
A
B
+24
+
|
ALTERNATOR
WET SENSOR
J6
J5
A1
PS
L1
L2
IN
PRESSURE
AUX INPUT
SENSOR
R69
U10
R20
R88
C11
R91
TP71
R93
R95
C7
J3
J4
R96
D10
TP76
TP78
C2 C1
_
WS
|
J1
XDCR
R1
R2
+24 _
S
NC COM NO
NC COM NO
RED
ALARM RELAY
RUN RELAY
TRANSDUCER
WARNING – Retain Owner's Manual.
Installation and operation of this equipment
requires detailed instructions as provided in
the Owner's Manual.
AVERTISSEMENT - Conserver le manuel du
propriétaire. L'installation et le
fonctionnement de cet équipement
nécessite des instructions détaillées fournies
dans le manuel du propriétaire.
ADVERTENCIA – Conserve el Manual de
Usuario. Para la apropiada instalación y
operación de este producto, se requiere
seguir detalladas instrucciones contenidas
en el Manual del Usuario.
Use 75 ºC CU wire rated 600 V min
Utilisez un fil nominale classifier
75 °C CU / 600 V min
Use alambre de 75 °C CU con
una clasificación mínima de
600 V.
Tighten terminals to 15 in-lbs.
Serrer les terminaux à 15 po-lb
Apriete las terminales a
15 pulgadas-libra.
YEL
BLK
25

Publicité

Table des Matières
loading

Table des Matières