Applications - Franklin Electric SUBDRIVE CONNECT PLUS Manuel Du Propriétaire

Masquer les pouces Voir aussi pour SUBDRIVE CONNECT PLUS:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

PRODUCT INFORMATION

Applications

Applications
NOTICE
Risk of damage to VFD, or malfunction can occur.
If a Corner-Grounded Delta power supply is used, all EMC jumpers at J10 and J11 must be
removed to prevent drive damage.
If an Open Delta Power Supply is used, the drive must be derated by 50% to prevent drive
damage and fault tripping. Refer to Incoming Power Supply on page 23.
NOTE: Franklin Electric MagForce submersible motors must be used with SubDrive Connect Plus submer-
sible (SUB) models. In these applications, the drive should be sized to match or exceed the maximum
amp rating of the motor based on the specific pump hp rating being used.
F F r r a a m m e e 2 2
Model
Volts
SDCP-SUB0723
SDCP-SUB1023
230
SDCP-CEN0723
SDCP-CEN1023
SDCP-SUB1043
SDCP-SUB1543
SDCP-SUB2043
460
SDCP-CEN1043
SDCP-CEN1543
SDCP-CEN2043
F F r r a a m m e e 3 3
Model
Volts
SDCP-SUB1523
230
SDCP-CEN1523
SDCP-SUB2543
SDCP-SUB3043
460
SDCP-CEN2543
SDCP-CEN3043
NOTE: Recommended for use on inverter duty rated motors (Centrifugal models). Follow motor manu-
facturer recommendations for cable lengths when using variable frequency drives.
Drives rated 230 VAC are suitable for use on a circuit capable of delivering not more than 5,000 RMS
maximum symmetrical amperes, 230 volts or equivalent.
Drives rated 460 VAC are suitable for use on a circuit capable of delivering not more than 5,000 RMS
maximum symmetrical amperes, 460 volts or equivalent.
NOTE: Maximum Output Amp ratings are 100% up to 3,300 ft (1,000 m) above sea level; derate Maxi-
mum Output Amps 1% for every 330 ft (100 m) above 3,300 ft (1,000 m).
8
Weight
3Φ Input
1Φ Input
lbs/kg
Motor HP
Motor HP
47.8 /21.7
7.5
48.3/21.9
10
43.8/19.9
7.5
44.2/20.0
10
48.1/21.8
10
48.5/22.0
15
48.9/22.2
20
44.0/20.0
10
44.4/20.1
15
44.8/20.3
20
Weight
3Φ Input
1Φ Input
lbs/kg
Motor HP
Motor HP
77.2/35.0
15
71.2/32.3
15
77.6/35.2
25
78.0/35.4
30
71.7/32.5
25
72.1/32.7
30
3Φ Input
1Φ Input
Maximum
Maximum
Output Amps
Output Amps
3
28
5
37
3
28
5
37
N/A
18
N/A
26
N/A
31
N/A
18
N/A
26
N/A
31
3Φ Input
1Φ Input
Maximum
Maximum
Output Amps
Output Amps
7.5
48
7.5
48
N/A
39
N/A
46
N/A
39
N/A
46
Pump Type
11
Submersible
18
Submersible
Centrifugal
11
Centrifugal
18
N/A
Submersible
N/A
Submersible
N/A
Submersible
N/A
Centrifugal
N/A
Centrifugal
N/A
Centrifugal
Pump Type
27
Submersible
27
Centrifugal
N/A
Submersible
N/A
Submersible
N/A
Centrifugal
N/A
Centrifugal
dV/dt
Filter
Yes
Yes
No
No
Yes
Yes
Yes
No
No
No
dV/dt
Filter
Yes
No
Yes
Yes
No
No

Publicité

Table des Matières
loading

Table des Matières