SPECIFICATIONS
Common Specifications
Voltage
Phase In
Frequency
Input from
Current (max)
Power Source
Power Factor
Power (idle)
Power (max)
Wire Gauge Size(s) Refer to
Voltage
Phase Out
Frequency Range
Output to Motor
Current (max)
Wire Gauge Size(s) Refer to
Factory Preset
Pressure Settings
Transducer Range
Temperature
Operating
Relative Humidity
Conditions*
Environment
Temperature
Storage**
Shelf Life
* Operating temperature is specified at full output power when installed as recommended. Refer to
"Over Temperature Foldback" on page 34
** Shelf life can be extended for one year by powering the drive for 60 minutes with no load.
Applicable Standards
Agency Safety Listings:
•
UL 61800-5-1
•
CSA C22.2 No. 274
•
UL 50
•
UL 50E
Enclosure Ratings:
•
UL Type 3R
SubDrive Connect Plus
208/230 ± 10% VAC or 460 ± 10% VAC, depending on model
Single-Phase or Three-Phase (208/230 VAC) or Three-Phase (460 VAC), depending on
model
60 Hz
Model dependent, refer to
"Input (Power) Wire and Fuse Sizing" on page 20
~ 0.75
230 VAC Frame 2/Frame 3: 25W 460 VAC Frame 2/Frame 3: 32W
Model dependent, refer to
"Input (Power) Wire and Fuse Sizing" on page 20
"Input (Power) Wire and Fuse Sizing" on page 20
208/230 VAC or 460 VAC depending on model
Three-Phase
30-60 Hz: Submersible Pump (Three-Phase)
15-60 Hz: Centrifugal Pump (Three-Phase)
60–120 Hz: Franklin Electric MagForce (Three-Phase)
Model dependent, refer to
"Applications" on page 8
"Output (Motor) Wire Sizing" on page 21
0 PSI for Setpoint 1 and Setpoint 2
Transducer: 0 to 5 PSI below Transducer maximum. The programmed drive Transducer
range is selectable from 100 to 300 PSI in 10 PSI increments.
–13 °F to 104 °F (–25 °C to 40 °C)
20-95%, non-condensing
Pollution Degree 2
–13 °F to 149 °F (–25 °C to 65 °C)
1.5 Years
SPECIFICATIONS
Common Specifications
51