PRODUCT INFORMATION

Description

The Franklin Electric SubDrive Utility UT3P is a variable frequency drive (VFD) designed to control and pro-
tect 3-wire, single-phase 230V motors, and 3-phase 230V motors, enhancing pump performance for resi-
dential and light commercial water system applications. When used with Franklin Electric motors ranging
from ½ to 2 HP, the UT3P drives a pump - motor assembly at variable speeds to maintain constant water
pressure, even as user demands (water flow) change.
The drive is designed to convert a conventional pump system to a variable speed
constant pressure system by simply replacing the pressure switch and control box.

Features

Configuration
Compatible with submersible and surface pumps
No programming required with easy DIP switch setup
Pressure sensor or transducer for water control
Works with small pressure tanks or existing larger tanks
Operation
Three LED indicators for system status and troubleshooting
30 Hz - 60 Hz for 3-Phase submersible; 15 Hz - 60 Hz for 3-Phase surface;
30 Hz - 63 Hz for 3-Wire (submersible only)
Accessory filtering available to remove AM radio frequency interference
Protection
Protection against short circuit, under-load, overload, overheat, under-voltage, over-voltage, surges,
open circuit, mis-wired 3-wire motor, and pressure sensor fault
Phase imbalance for 3-phase motors
Broken-pipe detection
User-defined under-load sensitivity
Soft-start feature prevents water hammer and increases motor life
Communication
USB port allows for easy firmware updates and easy Fault Log and Event Log downloads

Models

Submersible Applications

Model UT3P
w/Pressure Sensor
w/Pressure Transducer
Motor and pump HP are programmed through DIP switch settings. Refer to
power Setting (DIP SW1 – Positions 1–5)" on page

Surface Applications

Model UT3P
w/Pressure Sensor
w/Pressure Transducer
Part Number
½ HP
5870202303
5870202303XD
22.
230 V 3-Phase Motor Overload Protection Ratings (Amps)
Part Number
2.6 3.0 3.6 3.8 4.0 4.1 4.6 4.7 5.3 5.9 6.2 6.6 6.8 8.1 8.5 8.6
5870202303
5870202303XD 
230 V 3-Wire and 3-Phase
¾
HP
1 HP
1 ½ HP
"Submersible Motor Horse-
PRODUCT INFORMATION
2 HP
Description