Connection and operation
Material consumption
Material consumption can be estimated by calculating welding
time in minutes times wire feed speed (m/min) times weight per
meter of the welding consumables in use.
Technical data
Duty cycle 100% 40°C, A
Duty cycle  60% 40°C, A
Duty cycle max. 40°C, A
Wire feed speed, m/min
Torch connection
Wire diameter, mm
Gas pressure max., MPa (bar)
Touch Sense max. voltage, V
Touch Sense max. current, mA
Compressed air max., MPa (bar)
Dimensions (HxWxL), mm
Standards
Weight, kg
Protection class
1
Equipment marked IP23 is designed for indoor and outdoor applications.
1)
430
550
0.5-30.0
EURO
0.6-1.6
0.6 (6.0)
100
100
0.8 (8.0)
240x220x308
IEC60974-5.
IEC60974-10 CL. A
6.8
IP23
Software
In case of exchange of the control PCB, software must
be reloaded, using an SD card. Latest software can be
downloaded at
www.migatronic.com
Save the software on an SD card containing the folders
and one or more of the files shown below.
To order SD card, use item no 78861297.
MIGA_SW

Software update

• Insert the SD-card
• Turn on the machine
• Wait until the unit
indicates that the update
is complete
• Turn off the machine and
remove the SD card
• The machine is now ready for use
Error handling
Torch cooling fault
Cooling fault is indicated on machines in case of
insufficiant circulation of the cooling liquid due to
faulty connection, defective parts or choking. Check
that the cooling hoses are correctly connected, top up
the water tank and check welding hose and branches.
The cooling fault is cancelled by pressing shortly on
P
the
-key pad.
Gas control fault (IGC)
Gas fault exists due to a to low or high gas flow.
Make sure that the pressure on the gas flow is higher
than 2 bar and less than 6 bar, corresponding to higher
than 5 l/min and less than 27 l/min.
The fault is disconnected by adjusting the manual
gas flow to 27 l/min. The gas fault is reset by a short
P
pressure on the
-key pad.
Note: it is important that the stated gas supply can be
maintained during welding.
9
SIGMA
10006010.cry
(control software package)