TECHNICAL DATA

Supply voltage.
Phases :
Frequency :
Panel model:
Maximum nominal operating power (kW):
Maximum nominal operating current (A):
Dimension (HxLxP cm):
Weights: (kg):
Grade of protection:
Panel model:
Maximum nominal operating power (kW):
Maximum nominal operating current (A):
Dimension (HxLxP cm):
Weights: (kg):
Grade of protection:
Panel model:
Maximum nominal operating power (KW):
Maximum nominal operating current (A):
Dimension (HxLxP cm):
Weights: (kg):
Grade of protection:
Overload: %
Overboost:% of current overload or short
circuit phase/phase
Temperature limits:
Storage temperature limits:
Relative humidity (without condensate):
Max altitude:
Panel construction:
ENGLISH
400V ±10%
3
50-60 Hz
SP FC 1,5T-2
SP FC 2,2T-2
2 SP EFC 1,5T-2
2 SP EFC 2,2T-2
3 SP EFC 1,5T-2
3 SP EFC 2,2T-2
1,5
3,7
45x40x20
45x40x20
25 (SP FC-2 SP EFC)
25 (SP FC-2 SP EFC)
30 (3 SP EFC)
30 (3 SP EFC)
IP55
IP55
SP FC 7,5T-2
SP FC 11SD-2
2 SP EFC 7,5T-2
2 SP EFC 11SD-2
3 SP EFC 7,5T-2
3 SP EFC 11SD-2
7,5
15,5
45x40x25
80x60x30(SPFC)
80x80x30
(2 SPEFC - 3 SP EFC)
27 (SP FC-2 SP EFC)
32 (SP FC-2 SP EFC)
33 (3 SP EFC)
38 (3 SP EFC)
IP44
IP44
SP FC 30SD-2
2 SP EFC 30SD-2
3 SP EFC 30SD-2
30
61
120x80x30
36 (SP FC-2 SP EFC)
42 (3 SP EFC)
IP44
150% of nominal current x 60 sec. every 10'
> of the 200%
-10°C + 40 °C
-25 ÷ + 55
40% a 50°C max, 90% a 20°C.
1000 m (s.l.m.) every 100 m above 1000 m the current must be reduced by 2%.
Safety and functional standards applied:
-
EN 60204-1; Security electrical equipment.
-
EN 60439-1; Switchgear and controlgear assemblies
EMC standards applied:
-
CEI EN 61000-6-1; immunity for residential, commercial, and
light-industrial environments.
-
CEI EN 61000-6-2; industrial immunity.
-
CEI EN 61000-6-3; emission for residential, commercial and
light-industrial environments.
-
CEI EN 61000-6-4; industrial emission.
-
CEI EN 61000-3-2; harmonic current emission < = 16A (use
-
XLL1 line inductance to be installed on request, see electrical
connections on par. 8.1 and 8.2).
Emissions:
Powers ≤ 7.5kW:
compliant with residential environments: class B
Powers ≤ 7.5kW:
compliant with residential environments: class A
Immunity:
compliant with industrial environment.
EN 50598-2; Efficiency classes of converters and drive systems.
IEC 61800-9 (IE2);Adjustable speed electrical power drive systems
36
SP FC 3T-2
2 SP EFC 3T-2
3 SP EFC 3T-2
2,2
3
5,3
7,2
45x40x25
25 (SP FC-2 SP EFC)
30 (3 SP EFC)
IP44
SP FC 15SD-2
2 SP EFC 15SD-2
3 SP EFC 15SD-2
11
15
23
31
80x60x30(SPFC)
80x80x30
(2 SPEFC - 3 SP EFC)
32 (SP FC-2 SP EFC)
38 (3 SP EFC)
IP44
SP FC 4T-2
SP FC 5,5T-2
2 SP EFC 4-2
2 SP EFC 5,5T-2
3 SP EFC 4T-2
3 SP EFC 5,5T-2
4
9
45x40x25
45x40x25
25 (SP FC-2 SP EFC)
27 (SP FC-2 SP EFC)
30 (3 SP EFC)
33 (3 SP EFC)
IP44
SP FC 18,5SD-2
SP FC 22SD-2
2 SP EFC 18,5SD-2
2 SP EFC 22SD-2
3 SP EFC 18,5SD-2
3 SP EFC 22SD-2
18,5
37
80x80x30(SPFC)
80x80x30(SPFC)
100x80x30
100x80x30
(2 SPEFC - 3 SP EFC)
(2 SPEFC - 3 SP EFC)
32 (SP FC-2 SP EFC)
36 (SP FC-2 SP EFC)
38 (3 SP EFC)
42 (3 SP EFC)
IP44
5,5
12
IP44
22
43
IP44