9
REFERENCES CONTROL PANEL AND INTERNAL COMPONENTS
RIFERIMENTO
LL1
Amber warning light indicating panel fed.
!
LL2
Red warning light indicating alarms.
LL3
Green warning light indicating electropump one running.
LL4
Green warning light indicating electropump two running.
LL5
Green warning light indicating electropump three running.
Red warning light indicating thermal block of electropump one.
LL6
- blinking light for the first three interventions, fixed light at the fourth intervention.
LL7
Red warning light indicating thermal block of electropump two.
- blinking light for the first three interventions, fixed light at the fourth intervention.
LL8
Red warning light indicating thermal block of electropump three.
- blinking light for the first three interventions, fixed light at the fourth intervention.
LL9
SB1
LL10
WARNING: The command buttons AUTO / STOP are not active and the command is directed by the
electric switches.
Key for selecting operation of electropump one in:
- AUTO: yellow led LL3A lit: the electropump is started by the control board.
- MAN: yellow led LL3A lit: the electropump is started by holding down the key for more than 5
LL3A
SB2
- AUTO: yellow led LL4A lit: the electropump is started by the control board.
- MAN: yellow led LL4A lit: the electropump is started by holding down the key for more than 5
LL4A
SB3
FUNZIONE
Key for selecting panel operation with:
- INVERTER: yellow led LL9 lit.
- SYSTEM EXCLUDED: leds LL9 off and control panel programming enable
- PRESSURE SWITCH: yellow led LL10 lit: ATT.
seconds.
When the key is released, the electropump stops and the led LL3A goes out.
Press the key
and select automatic starting of the electropump
again (the led LL3A lights up).
Key for selecting operation of electropump two in:
seconds.
When the key is released, the electropump stops and the led LL4A goes out.
Press the key
and select automatic starting of the electropump
again (the led LL4A lights up).
ENGLISH
41