12.1 RESEARCH AND SOLUTION PROBLEMS: PAGE INFO.
Display Indication
AL4
Pumps blocked, no phase motor
AL8
AL16-
N° CODE ALARM
AL32
AH2O
AL64
Lack of water, minimum level.
13 SYSTEM OPERATION WITH PRESSURE SWITCHES
Hold down the key SB1 for three seconds
electropumps start, controlled directly by the pressure switches.
ATTENTION! The AUTO and STOP buttons of each electropump are NOT active.
To exclude the individual electropumps isolate:
- FU2 for M1,
- FU3 for M2,
- FU4 for M3,
- Turn the isolating switch on the panel QS1 to "0".
MODBUS MAPPING
14
Protocol Reference:
Comunication configuration:
Terminals connections:
Related Parameters:
Address
0000
Instantaneous pressure
0001
Set pressure
Unit of measure 1:bar
0002
Inverter control frequency
0010
0011
Pump 1 instantaneous current
0012
Pump 2 instantaneous current
0013
Pump 3 instantaneous current
Description
Transducer connections
interrupted or inverted.
Incorrect calibration amperes
scale
Inverter Protection . Code List
Inverter Alarm
Overpressure
Minimum pressure
MODBUS application protocol specification V1.1b
9600/8/1/P
KL4 board terminals 20,21,22
Page [1.13] node address assignment in the modbus network
"RC Modbus" page under password 31109 for the enabled of the command parameters (see 3rd part)
1st Part: Reading numeric values - modbus command "0x04"
ENGLISH
Error Conditions
Check the electrical connections and the efficiency of transducers.
NB: in a sistem with a single transducer in the case of failure AL T1 the unit
automatically searches for the second transducer, if it is connected, it still
works in regolation otherwise the system pass to the switches control.
Unlock the pump manually.
Check the fuses of the motors.
Switch off power to the panel.
After waiting 5 minutes,re-supplay.
If the error persists, replace the inverter.
Shut down the plant.
Check if the parameter 124 if is properly set
Check the presence of water in the plant.
Enable the electric pumps at the march.
Check the presence of water in the plant.
Enable the electric pumps at the march.
t
he led LL10 indicates the operating condition and all the
Description
60
Restore sequence
Factor
Bar x100 // meters
Bar x100 // meters
Hz x10
A x10
A x10
A x10