11.5
CONFIGURATION HOME
PAGE MENU
ENGLISH
2.7 Max. reference
Inverter speed maximum threshold.
2.8 Jog frequency
Inverter working frequency in manual
operation.
2.9 Acceleration time
Inverter starting slope from 0 to 50 Hz.
2.10 Deceleration time
Inverter stopping slope from 50 to 0 Hz.
2.11 Direction of rotation
Direction of motor rotation.
0) Clockwise
1) Counter-clockwise
SYSTEM CONFIGURATION WITH TECHNICAL PASSWORD: 31100
(SET I/O MENU)
Viewing page of the configuration menu.
1: Set plant
2: Set inverter
3. Set inputs outputs
4: Managing Alarms
5: Electrical values
6: Software version
To enter the page of the menus press the button SB9
password.
Type in the user password 31100 and enter in the menu SET plants listed below.
Press SB6 –SB7
Press SB8 –SB10
Press SB9
to confirm the data.
Press SB1
to return to the HOME PAGE monitor.
0 - 200.0 Hz
0 - 200.0 Hz
001.0 - 255.0 s
001.0 - 255.0 s
1
1
to scroll through pages of parameters.
2
2
to decrease or increase the data.
55
50 Hz
50 Hz
001.0 s
002.0 s
0 - 1
appears the page insert
0