3.1.3 – List of cables
The cables required for the installation of GD0N may vary depending on the type and quantity of devices to be installed; figure 13 shows the cables
needed for a typical installation; no cable is supplied with GD0N.
13
E
D
B
A
C
Table 5: List of cables
Connection
[A] STOP input
[B] OPEN input
[C] PHOTO input
[D] FLASH input
[E] Radio aerial
Note 1 – For the PHOTO, STOP and OPEN cables, there are no special contraindications to the use of a single cable that groups together multiple
connections; for example, the STOP and OPEN inputs can be connected to the KS100 selector switch using a single 4x0.25mm
WARNING: – the cables used must be suitable for the type of installation; for example, an H03VV-F type cable is recommended for
indoor applications

3.2 - PREPARING THE ELECTRICAL SySTEM

With the exception of the plug and the power cable, the rest of the system
uses extra-low voltage (approx. 24V); the wiring can therefore be done by
personnel that is not properly qualified, provided that all the instructions in
this manual are carefully observed.
After selecting the position of the various devices (refer to figure 13) you
can start preparing the conduits for the electrical cables connecting the
devices to the control unit.
The shock-resistant conduits are designed to protect the electrical cables
and prevent accidental breakage.
Install any fixed control close to the door but away from moving parts and
at a height of 1.5m.
10 – English

Cable type

Cable 2 x 0.25 mm
2
Cable 2 x 0.25 mm
2
TX Cable 2 x 0.25 mm
2
RX Cable 3 x 0.25 mm
2
Cable 2 x 0.25 mm
2
RG58 type shielded cable
3.2.1 – Connection to the Electrical Mains
Although the connection of GD0N to the electrical mains is beyond the
scope of this manual, we wish to remind you that:
• The power supply line must be laid and connected by a qualified
professional electrician.
• Have a suitably protected 16A "schuko" outlet installed, where
you can plug in GD0N.
• Make sure that the power supply cable does not hang over mov-
ing parts or hazardous areas.
• The electric line must be grounded and protected against short
circuits; a bipolar disconnection device must also be present with
contact separation of at least 3mm, which allows the power sup-
ply to be disconnected during the installation and maintenance of
the GD0N.
C
Maximum length allowed
20 m (note 1)
20 m (note 1)
20 m (note 1)
20 m
20 m (recommended less than 5 m)
cable.