Initial Checks - Nice MhouseKit GD0N Instructions Et Avertissements Pour L'installation Et L'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Terminals
Function
Aerial
1-2
OPEN
3-4
STOP
5-6
PHOTO
3-7
Phototest
6-8
Flashing light
9-10
3.4 - MAIN HOOKUP
The connection of the GD0N control unit to the mains must be
made by a qualified electrician.
To carry out tests, insert the plug for GD0N in a power outlet; if necessary,
use an extension cord.
43

3.5 - INITIAL CHECKS

As soon as the control unit is energised, you should check the following:
1 Make sure that the LED [A] flashes regularly, with about one flash per
second.
44
A
TABLE 6
Description
Radio receiver aerial connection input. The FL100 has a built-in aerial, alternatively an
external aerial can be used or the small piece of wire that is already connected to the
terminal can be left, which acts as an aerial.
Input for manoeuvre control devices; "Normally Open" type contacts can be connected.
Input for the devices which block or eventually stop the manoeuvre in progress. Con-
tacts like "Normally Closed", "Normally Open" or constant resistance devices can be
connected using special procedures on the input. Additional information on STOP can
be found in paragraph "5.3.2 STOP input".
Input for safety devices such as PH00 photocells. Cut-in during closure, inverting the
manoeuvre.
"Normally Closed" contacts can be connected. The PHOTO input is factory set, short-
circuited by means of a jumper between inputs 3 and 7 of the terminal. Additional infor-
mation on PHOTO can be found in paragraph "3.3.4 PH00 Photocells (optional)".
All safety devices are controlled each time a manoeuvre is performed and the manoeu-
vre is only performed if the test has a positive outcome. This is possible by means of
a special connection type; the "TX" photocell transmitters are powered separately in
respect to the "RX" receivers. Additional information on connections can be found in
paragraph "5.3.1 Phototest output".
An FL100 flashing light with a 12V 21W car bulb can be connected to this output. Dur-
ing the manoeuvre it flashes at intervals of 0.5s.
2 If the system is equipped with the PH00 photocells, make sure that the
SAFE LED [B] shown in figure 45 flashes (on both TX and RX). The type of
flashing is irrelevant, it depends on other factors; what matters is that it is
not always off or always on.
45
3 If the system is equipped with the KS100 key-operated selector switch,
make sure that the night light [C] is on.
46
4 If the above conditions are not satisfied, you should immediately switch
off the power supply to the control unit and check the cable connections
more carefully. For more useful information see also chapters 5.5 "Trou-
bleshooting" and 5.6 "Diagnostics and Signals".