2.2) Typical system

Figure 2 shows a typical system for automating a sliding gate using ROBUS350.
1
4
2
2
D
1
Key-operated selector switch
2
Photocells on post
3
Photocells
4
Main fixed edge (optional)
5
Main movable edge
6
"Open" stop bracket
7
Rack

2.3) List of cables

Figure 1 shows the cables needed for the connection of the devices in a typical installation; Table 2 shows the cable characteristics.
!
: the cables used must be suitable for the type of installation. For example, an H03VV-F type cable is recommended for
indoor applications, while an H07RN-F is suitable for outdoor applications.
Table 3: list of cables
Connection
A: Power line
B: Flashing light with aerial
C: Photocells
D: Key-operated selector switch
E: Fixed edges
F: Movable edges
Note 1: power supply cables longer than 30 m may be used provided they have a larger gauge, e.g. 3x2.5mm2, and a safety grounding
system is provided near the automation unit.
Note 2: A 2x1mm2 cable is needed if the "BLUEBUS" cable is longer than 30 m (max. 50 m).
Note 3: A single 4x0.5mm2 cable can be used instead of two 2x0.5mm2 cables.
Note 4: Please refer to Chapter "7.3.2 STOP Input" in situations where there is more than one edge, for information about the type of con-
nection recommended by the manufacturers.
Note 5: special devices which enable connection even when the leaf is moving must be used to connect movable edges to sliding leaves.

3) Installation

!
The installation of ROBUS350 must be carried out by qualified personnel in compliance with current legislation, standards
and regulations, and the directions provided in this manual
4
3
5
7
6
F
E
8
Secondary fixed edge (optional)
9
flashing light with incorporated aerial
10 ROBUS350
11 "Closed" stop bracket
12 Secondary movable edge (option)
13 Radio-transmitter
Cable type
N°1 3x1.5mm
2
cable
N°1 2x0 5mm
cable
2
N°1 RG58 type shielded cable
N°1 2x0.5mm
2
cable
N°2 2x0.5mm
2
cables (note 3)
N°1 2x0.5mm
cable (note 4)
2
N°1 2x0.5mm
2
cable (note 4)
3
8
C
Maximum length allowed
30m (note 1)
20m
20m (recommended less than 5m)
30m (note 2)
50m
30m
30m (note 5)
9
12
2
11
10
13
F
A
B