sufficiently sturdy.
• Make sure that the mounting surfaces of the photocells are flat
and that they enable the proper alignment between TX and RX.
• Make sure that the minimum and maximum clearances specified
in fig. 8 are observed.
8
C
• Pay attention in particular to the methods for securing the head
of the guide and the brackets to the ceiling. The head of the guide
will have to bear all the strain of opening and closing the door; the
ceiling-mounted brackets will have to bear all the weight of GD0N.
In both cases, the wear and deformations which may occur in time
must be taken into consideration.
• The gearmotor should be mounted at the centre of the door, but
a small deviation from this position is permissible. This may be
required to mount the OSCILLATING ARM to the side of the handle
(Figure 9).
9
8 – English
D
2970 mm
410 mm
B
0÷400 mm
• Make sure that, in the position corresponding to the door, or
slightly to the side, (see positions "A" and "B") the conditions
are suitable for mounting the head of the guide; in particular, the
material should be sufficiently sturdy and compact.
Make sure that GD0N can be mounted on the ceiling along posi-
tion "C" using the mounting brackets.
If the door to be automated is an overhead type with springs or
counterweights, it will be necessary to install an OSCILLATING
ARM, which must be mounted next to the handle (Figure 9).
• Make sure that distance [E] in Figure 10, i.e. the minimum dis-
tance between the upper side of the guide and the maximum point
reached by the upper edge of the door, is no shorter than 65 mm
and no longer than 300 mm. Otherwise GD0N cannot be installed.
10
B
0÷400 mm
If the door closes a room that has no other means of access, we
recommend installation of the EXTERNAL RELEASE KIT (figure 11
and 11a). In fact, in this situation, a simple power failure may pre-
vent access to the area.
N.B.: the oscillating arm and external release kit are supplied with
the related assembly instructions.
11
E
65÷300 mm

Publicité