Diagnostics And Signals; Flashing And Courtesy Lights - Nice AVIO600 Instructions Et Avertissements Pour L'installation Et L'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

5.6 – TROUBLESHOOTING
The following table contains instructions to help you solve malfunctions or errors that may occur during the installation stage or in case of failure.
90
5.7 – DIAGNOSTICS AND SIGNALS
A few devices issue special signals that allow you to recognise the operat-
ing status or possible malfunctions.
5.7.1 – Photocells
The photocells are equipped with a "SAFE" LED (Figure 91) that allows
you to check the operating status at any time.
LED "SAFE"
Status
Off
The photocell is not powered or is faulty
3 quick flashes and a
Device not recognised by the control unit
second's pause
1 very slow flash
The RX receives a perfect signal
1 slow flash
The RX receives a fair signal
1 quick flash
The RX receives a poor signal
1 very quick flash
The RX receives a very poor signal
Always on
The RX does not receive any signal
5.7.2 – Flashing and courtesy lights
During the manoeuvre the flashing light flashes once every second, while
the courtesy light is always on; when something is wrong the flashes
Quick flashes
Status
1 flash
BUS error
1 second pause
1 flash
2 flashes
Photocell activated
1 second pause
2 flashes
3 flashes
Activation of the "motor force" limiting device
1 second pause
3 flashes
4 flashes
STOP input activation
1 second pause
4 flashes
B
C
Flash BUS Stop Sbs Open
[A] Led
TABLE 14
TABLE 15
D
91
Action
Make sure that there is voltage (approx. 8-12 V
cell's terminals; if the voltage is correct, the photocell is probably
faulty
Repeat the recognition procedure on the control unit.
Make sure that all the photocell pairs on BUS have correct
addresses
Normal operation
Normal operation
Normal operation but you should check the TX-RX alignment and
make sure the glasses are clean
It is at the limit of normal operation, you should check the TX-RX
alignment and make sure the glasses are clean
Check to see if there is an obstacle between TX and RX. Make
sure that the LED on TX flashes once slowly. Check the TX-RX
alignment
are more frequent (half a second); the light flashes twice with a second's
pause between flashes. The diagnostic flashing itself is signalled by the
courtesy light.
Action
At the starting of the manoeuvre, the devices present do not cor-
respond to those recognised; check and if necessary try repeating
the recognition process. (5.3.3 "Recognition of Other Devices").
One or more devices may be faulty; check and, if necessary,
replace them.
At the start of the manoeuvre, one or more photocells do not
enable it; check to see if there are any obstacles.
If there is an obstacle impeding the movement no action is
required.
During the movement, the door experienced excessive friction;
identify the cause.
At the start of the manoeuvre or during the movement, the STOP
input was activated; identify the cause.
G
E
F
Led SAFE
) on the photo-
English – 21

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Avio1000

Table des Matières