4.2 INSTALLATION
The device can be installed into pipes using our special fitting system S020.
The fitting 4 must be installed into the pipe according to the installation guidelines within
section 4.1 and within the instruction manual of the fitting. Then:
- Insert the plastic nut 3 onto the fitting 4 and snap the plastic ring 2 into the guide
bush 5.
- Insert the sensor into the fitting ensuring the arrow on the side of the housing
indicates the flow direction and ensuring the cable glands show the down stream
direction and the alignment of the electrodes is per pen dic u lar to the flow direction.
The plastic nut must only be tightened by hand!

4.3 GENERAL ELECTRICAL CONNECTION

- Use cables with a temperature limit of 105°C minimum.
- For normal operating conditions the measuring signal can be transmitted by a
shielded cable of 0.75 mm
- The cable must not be installed in combination with carrying lines with a higher
voltage or frequency.
INSTALLATION
1
Electrodes
2
3
5
4
2
cross section.
24
Flow direction
8041