Transistor output
pulse output, NPN and PNP, open
(Hall version)
collector, max. 100 mA, frequency
up to 300 Hz, duty cycle 1/2 ±10%
NPN output: 0,2-36 V DC
PNP output: supply voltage
Transistor output
pulse output, NPN, open collector,
(Hall Low Power
max. 10 mA, frequency up to
version)
300 Hz, duty cycle 1/2 ±10%
Coil output
sine-wave signal, frequency up to
300 Hz, about 2.8 mV peak-to-peak/
Hz under a 50 kW load
English
20
7.
insTAllATion AnD
commissioninG
safety instructions
danger
risk of injury due to high pressure in the installation.
• Stop the circulation of fluid, cut off the pressure and
drain the pipe before loosening the process connections.
risk of injury due to high fluid temperatures.
• Use safety gloves to handle the device.
• Stop the circulation of fluid, and drain the pipe before
loosening the process connections.
risk of injury due to the nature of the fluid.
• Respect the prevailing regulations on accident prevention
and safety relating to the use of hazardous products.
danger
risk of injury due to electrical voltage.
• Shut down and isolate the electrical power source
before carrying out work on the system.
• Observe all applicable accident protection and safety
regulations for electrical equipment.
English
22
electrical connection
type of connector
cable type
2508 female connector
For the Hall and Hall Low
(supplied), with order
Power versions:
code 438811
• shielded, max. 50 m
• 5 to 8 mm in diameter
• wires between 0,25 and
For the sinus version:
• shielded, max. 10 m
• 5 to 8 mm in diameter
• wires between 0,25 and
Warning
risk of injury due to non-conforming installation.
• The electrical and fluid installation can only be carried out
by qualified and skilled staff with the appropriate tools.
• Observe mounting instructions of the fitting.
risk of injury due to an uncontrolled restart.
• Ensure that the restart of the installation is controlled
after any interventions on it.
Warning
risk of injury if the fluid pressure/ temperature
dependency is not respected.
• Take account of fluid temperature-pressure
dependancy according to the nature of the materials
the fitting is made of (see Tab. 1).
• Comply with the Pressure Directive 97/23/EC.
1,5 mm
in cross section
2
1,5 mm
in cross section
2
English
English
21
21
23
23