GB iveo initial operation/Setting by radio
6.1. Limit position setting and programming the first transmitter
6.1.1. Semi-automatic setup-mode, deletion and semi-automatic setting of the
end positions
in operation bottom position, top stop/release
When the movement is interrupted twice during operation, the system is in semi-
automatic setup-mode. The drive will only find the upper end limit automatically.
Important: A limit stop for the upper end limit is necessary!
First the lower end limit has to be run-up to. From there move against the upper limit
stop without interruption, until the motor is automatically switched off.
Caution!
Only connect the radio motor that you wish to program to the mains. It is not possible
to program more than one motor at the same time.
Operation
or
or
1 s
Drive
Move the motor with the UP or DOWN button downwards
to the requested lower end limit.
Run against the limit stop at the top without stopping; the
motor stops automatically. The correct direction of rotation
assignment has been made.
Perform a test run: The drive moves up against the limit stop
and relieves shortly.
Press the PROG button at the transmitter.
The transmitter is now permanently programmed.
60