Peak Readings (Maximum) - MSA Orion plus Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Peak Readings (MAXIMUM)

The Maximum flag appears in the upper portion of the display to
show the highest levels of gas recorded by the Orion plus Multigas
Detector since:
Turn-ON
Short Term Exposure Limits (STEL)
The STEL flag appears in the upper portion of the display
to show the average exposure over a 15-minute period.
When the amount of gas detected by the Orion plus Multigas
Detector is greater than the STEL limit, the:
Alarm sounds and Alarm lights flash
STEL flag flashes.
The STEL alarm is calculated over a 15-minute exposure.
Calculation examples are as follows:
Assume the Orion plus Multigas Detector has been running for at least 15
minutes.
10-minute exposure of 35 PPM
5-minute exposure of 5 PPM:
(10 minutes x 35 PPM) + (5 minutes x 5 PPM)
Assume the Orion plus Multigas Detector was turned on five minutes ago.
5-minute exposure of 15 PPM:
(5 minutes x 15 PPM) + (10 minutes x 0 PPM)
15 minutes
15 minutes
= 25 PPM
= 5 PPM
3-11