Using the Orion plus Multigas Detector

Turning ON the Orion plus Multigas Detector

Installing the Battery Pack (FIGURE 3-1)

Figure 3-1. Battery Pack Installation
1. Slide the battery pack toward the top of the instrument.
2. Swing the battery pack up and into the body of the instrument.
3. Secure the battery pack by installing the two screws in the bottom
two corners of the battery pack and instrument.
NOTE: The screws must be snug to ensure that the battery pack
properly seals to the instrument. Do not over-tighten.
4. Once the battery pack is installed, the Orion plus Multigas Detector
turns ON.
A calibration check must be performed after switching bat-
tery packs to assure accuracy of readings.