Adjustments
Opening width side
direction P (with shifting of the
laying cluster into running bond)
5.10

Setting positioning adapters

clamping
The HVZ-UNI with its powerful side clamping action, is capable to
shift not dentated layers of pavers which are palletized in cross bond
into the running bond.
To do this special positioning adapters (special accessories) are fixed
on the C-profiles of the side clamp. The number of positioning
adapters, which are needed, is identical with the numbers of rows in
main clamping direction (for example 7 adapters, as shown in this
example, of the paver layer or 5 adapters as shown on the example,
mounted on the C-profile)
Direction of main gripping
The distance between the head of the adapter and the C-profile is
usually half the length of one block, when half bond is required.
In the example shown, length of the paver is 20 cm,
divided by 2 = 10 cm.
On the paver layer showed here as an example, on the right hand
side adapters to touch row 1, 3, 5 and 7 should be mounted roughly
in the right distance towards one another.
On the C-profile on the left-hand side the adapters are mounted to
touch row 2, 4 and 6.
Hydraulically open the main clamp, which is already set correctly,
completely, position it over the pack of pavers, clamp hanging freely.
Close side clamping completely.
Hanging height should be high enough, so the side clamping is not
touching the pavers.
Rough setting of both side clamping parts via screw P until the
length of the layer + half length of one paver (in example shown 5 x
20 + 10 = 110 cm, is showing underneath the scale. See illustration)
Measure the distance between the two C-profiles, do the fine tuning
via screw P. So the measurement is about 3 – 4 mm larger than the
actual length of the laying cluster.
Doing this, you make sure that the single pavers are not compressed
together completely but still have small joints between one another
in the side clamping direction.
This is necessary in order to get the joint width of about 2 ½ mm, as
required by the specifications.
Open side clamping completely.