GILGEN ASL-S Instructions D'installation Et D'utilisation page 64

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

- Determine the position of the Halfen rail (29) for the gate driver on the gate and mark the holes.
Y-axis
For single-winged doors the latter is determined by the position of the drive system (i.e. above or behind the
clearance opening).
Attention:
The minimum distances between the drive unit (21) and the guide bearing (16) must be
observed.
X-axis
Is determined by the door frame and - insofar as possible - by the distance between the ceiling. Fig. 7, Fig. 8
Note:
Distance between X-axis and ceiling 215 - 285 mm:
The drive unit (21) can be mounted to the ceiling by means of a Halfen frame (13).
Distance exceeding 285 mm:
The Halfen frame (13) and the return bearing (16) are mounted by means of a wall bracket.
30 31
29
Wall bracket
Art. no. 0602-326
- Using the included Tubtara riveting nut (30) and the hexagon socket screws (31), mount the Halfen rail (29) onto
the door in the position which has previously been determined.
- Mark the fixing holes for the Halfen frame (13) and the return bearing (16) and drill them 65 mm deep, using a
ø12drill.
- If a wall bracket is used for the installation, adjust the measure accordingly. Fig. 8
0602-999-11c_2008.09.p65
Fig. 7
X
Intermediate plate
Art. no. 0602-625
16
0602-999/11c
Art. no. 0602-326
13
X
110
ASL-S
9-40
Wall bracket
View A
510
A
Fig. 8