4.3
Assembly of motor, pump and follower plate
Spur gear motors
Put the motor onto the flange and
>
screw it on using the enclosed coun-
tersunk head screws, washers and
nuts.
Fasten the cable with the grommet
>
on the support (1). Fasten the cable
on the marking using cable ties
Plug the 4-pole connector in at
>
switch cabinet XS 1, the 8-pole
connector at switch cabinet XS 2
and screw them down.
Three-phase motor
Put the motor onto the flange and
>
screw it on using the enclosed coun-
tersunk head screws.
Have the motor cable connected in
>
the motor's cable terminal box as
shown in the installation guide.
Have electrical installation done by
experts only!
Compressed-air motor
The motor is mounted and connected
from factory. If not:
> Place the motor on the flange and
tighten it with the provided counter-
sunk screws.
> Connect the compressed air hose of
the service unit to the motor
properly.
Operating instructions VISCOFLUX mobile S
1
2
3
51 / 96