Operation With Compressed Air Motors; Preparing Drum Emptying; Drum Emptying - FLUX VISCOFLUX mobile S Notice D'instructions Originale

Système de vidange de fût pour les substances à haute viscosité sans pouvoir d'écoulement propre
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

5.2

Operation with compressed air motors

5.2.1

Preparing drum emptying

Make sure that a connection to the
>
compressed air supply is ensured
within spitting distance of the drum
emptying place.
For changing the position, lower the
>
pump with follower plate to approx.
30 cm above floor level (1).
Too much lowering can damage
>
the follower plate when changing
position.
5.2.2

Drum emptying

Before connecting the compressed
>
air set the ball valve (1, page 56)
horizontally to "off".
Lift the follower plate above drum
>
level using the hand-held control unit
(2).
The hand-held control unit has two
speeds:
slow movement (3)
fast movement (4)
Align the follower plate centre above
>
the drum.
If you have drums with a smaller
>
opening place the follower plate
eccentrically at the edge of the drum
(7).
Do not close the locking brakes at
>
the trolley.
Open the ball valve (5) (ball valve (6)
>
remains closed) to let the air escape
from the drum.
Lower the pump system until the
>
follower plate is supported on the
material.
The lowering of the pump system
on the medium must be supported
manually (7).
Close the ball valve (5).
>
Operating instructions VISCOFLUX mobile S
1
2
6
7
4
3
5