Control unit

Various control units in combination with the process device can be used with the
VISCOFLUX mobile S drum emptying system. An exemplary variant is shown (with
pump rotation speed setting on the switch cabinet).
1
2
3
4
5
Fig. 5: Control unit — front view
No.
Component
1
FLUXTRONIC® optional (separate instructions)
2
Switch cabinet lock
3
Operating mode: Manual-0-batch
4
Motor: Start
5
Motor: Stop/reset
6*
Illuminated push-button with warning lamp bottom limit reached
7
Pumps: anticlockwise, clockwise rotation
8
Pump rotary speed setting (optional)
9
Master switch
* Function of the illuminated push-button: When the end position is reached the pump motor
switches off and the illuminated push-button lights up. If the push-button is now pressed the
pump motor runs as long as the push-button is actuated.