Intended use

The pump is used for the fast and safe emptying or filling of containers. It can pump all
kinds of fluids according to the design.
In hazardous areas, the MINIFLUX is used with motors that are suitable for the use in
ZONE 1 (category 2) according to the valid Explosion Protection Directive.
The assembly and the operation of the pumps and motors are performed outside the
container.
Manual as well as remote operation is
For stationary use, the pump has to be constantly observed.
The motor can be released from the pump.
The mounting position is horizontally.
As a pump drive commutator and compressed-air motors are available.
1.1
Restrictions, limits of permitted use
Do not expose the pumps to the weather.
Observe minimum and maximum temperatures.
Observe the chemical resistance and the explosion protection.
The pump is connected to the container.

Foreseeable misuse

Pump and accessory material must always be suitable for the product to be transferred
(see resistance chart).
Observe the operating instructions when changing the liquid. Take possible chemical
reactions and the resulting health hazards and material damage into account.
Only operate the motors in conjunction with the pumps in the corresponding liquids.
Non-observance may result in damage to the pump and the motor and operator injury.

Description of pump

Union nut S 60x6
IBC container side
( z.B. S60x6)
Clamp
Connection for
equipotential bonding
Attention!
Non-observance of the safety instructions may result in operator
injury and damage to the pump and the motor.
possible.
Hose connection G1 ¼ A
Mounting option
for a support
MINIFLUX
Ex-marking
Union nut RD 65x1/6
motor side
11 / 32