FLUX VISCOFLUX mobile S Notice D'instructions Originale page 52

Système de vidange de fût pour les substances à haute viscosité sans pouvoir d'écoulement propre
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Follower plate
Mount the follower plate to the clamp
>
connection of the pump (4).
Tighten the clamp screwing.
>
Pump
Move the process device with the
>
mounted motor above the pump.
Adjust the clutch dogs to make them
>
intertwine.
Cautiously lower the motor.
>
Screw the pump tightly onto the
>
flange using four hexagon head
screws.
Connect the compressed-air hose to
>
the follower plate (5).
Ensure tight fit!
>
Connect the compressed-air hose to
>
the compressed-air supply.
>
Prior to installation and putting into service, visually inspect the drum emptying
system and the hoses.
>
Connect the hose (adjusted to the material) to the outlet socket of the pump.
52 / 96
Operating instructions VISCOFLUX mobile S