Functional principle

The VISCOFLUX mobile S drum emptying system consists of the mobile process device,
a FLUX eccentric worm-drive pump with motor and the follower plate. At the start of the
pumping process, the follower plate is supported on the pumped material in the drum.
The action of the eccentric screw pump creates a vacuum which pulls the follower plate
down automatically. The process seal of the follower plate hermetically seals the pumped
material even in conical drums and at the same time ensures that the pumped material is
stripped off at the drum wall.
After having switched on the pump drive the follower plate is automatically lowered. For
lifting the follower plate compressed-air needs to be blown into the drum.
The compressed air presses the follower plate upward and at the same time holds the drum
down at the ground. When the follower plate has reached the top of the drum it has to be
lifted from the edge with the handheld control unit.
3.2

Technical data

Dimensions / weight
Dimensions
Weight
Drum diameter
Lifting capacity
Max. lifting height
Surrounding
temperature
Energy supply
For process device with three-phase motor, spur gear drive motor
10-00122425 / 10-00122426
Protection class
3 phase AC supply voltage
Connecting cable
Pump motor
Drive unit
Battery
Charging time
Compressed-air supply
>
42 / 96
mm
See dimension sheet on page 44.
On request. Varies depending on pump length, pump
kg
motor and diameter of the follower plate.
As standard, dimensioned for drum diameters 560 mm
and 571.5 mm, conical drums with diameters 515 mm
at bottom and 550 mm at top, with a height of 970 mm
mm
and drums with a diameter of 571.5 mm with a reduced
opening width of 540 mm
kg
100
mm
See dimension sheet on page 44
0 – 40 °C
°C
IP 66
208- 400 VAC / 50/60 Hz
3/N/PE with potential-free neutral conductor (N)
opposite to outer conductor (L1-L3)
5 m with Cekon connector
Various driving motors available on request
e.g. three-phase motor, spur gear drive motor
Maintenance-free lead acid battery 24 V / 9 Ah
Charging is done during operation with plugged-in
plug (when using a control unit, the main switch must
be set to "on")
4 – 5 hours at empty battery
6-8 bar, dry
For spur gear motors with frequency converter, the operator must use
all-current sensitive residual current circuit breakers of type B or B+.