Lower the pump system until the fol-
>
lower plate is supported on the mate-
rial.
The lowering of the pump system on
the medium must be supported man-
ually (7).
Close the ball valve (5).
>
>
If not already connected, connect the material hose to the pump.
>
Switch the pump on.
The pump unit with the follower plate moves into the drum
>
Immediately switch off the pump when rising medium is no longer exiting!
Danger to operator and machine
>
>
>
>
>
5.1.3

Lifting the follower plate out of the drum

Switch the pump off.
>
Connect the compressed-air supply
>
(1).
Slowly open the ball valve (2) and let
>
the compressed air flow into the
drum slowly.
The pump unit with the follower plate
moves upward and the drum is kept on
the ground.
>
Close the ball valve (2) when lifting by compressed air is no longer required or air
escapes at the upper rim of the drum.
>
Move the lifting sledge further up until the follower plate is located above the drum.
>
Move the process device away from the drum.
>
For changing the position, lower the pump with follower plate up to approx. 30 cm
above floor level.
>
>
>
>
54 / 96
Do not leave the drum emptying system unattended.
When the maximum height is approached there might be danger of
tilting due to shifting the balance point.
Immediately switch the pump off when no material is transported.
Danger of damage to materials and pump!
Never let the pump run against a blocked outlet.
When lifting the follower plate, ensure that hoses and cables are not
clamped and not subjected to tensile force.
Consider the ceiling height, pipes and cable ducts at the emptying place!
Remove pumped material from the floor and dispose of it in accordance
with environmental regulations.
Remove power cord and compressed air line when changing the position.
Operating instructions VISCOFLUX mobile S