6.1
SPECIFICATIONS
Specification in relation to the process
Flow measurement
Measurement type
Measuring range
Measuring error
Linearity
Repeatability
(*) Under reference conditions i.e measuring fluid = water, ambient and water temperatures of 20 °C,
applying the minimum inlet and outlet pipes straights, matched inside pipe dimensions
o. R. = of Reading
o. F.S. = of Full Scale (10 m/s)
Piping installation
Fittings
Pressure rating
with a PVDF sensor
with a st. steel sensor
Fluid temperature
with a PVDF sensor
with a st. steel sensor
Conductivity of the fluid
Materials contacting the fluid
Sensor armature
Electrodes
Earth ring
(version with PVDF sensor)
Seals
Electrode armature
(version with st. steel sensor)
Fluid Control Systems
SPECIFICATIONS
Electromagnetical measurement
0,1 to 10 m/s (0.3 to 32.8 fps)
1) with individual works calibration (on request) or Teach-In:
+/- 2 % o. R. (1-10 m/s) (*)
2) with standard mean K-Factor:
+/- 4 % o. R. (1-10 m/s) (*)
+/- (1 % o. R. + 0,1% o. F.S.) (*)
0.25 % of measured value
Stainless steel, brass or plastic (PVDF, PP, PVC)
Solvent/fusion spigots, threaded ports (G, NPT, Rc),
buttwelding ends, flange, Tri-clamp - see instruction manual
S020 - Ident. No.- 429633
PN 6
PN 16
0 to 80 °C (32 to 176°F)
-25 to +110 °C (-13 to +230 °F)
min. 20 µS/cm
PVDF or Stainless-steel 316L (DIN 1.4404)
Stainless-steel 316L (DIN 1.4404)
Stainless-steel 316L (DIN 1.4404)
EPDM (standard on versions with a stainless steel sensor)
FPM (standard on versions with a PVDF sensor)
PEEK
36
8045