Installation instructions, only for experts

Fault
Description
number
-5
No operating unit connected.
Operating unit no longer connected
-10
after at least one was recognised
during launch.
-21
Heater temperature sensor broken.
Heater temperature sensor short-
-22
circuiting.
-24
Bench temperature sensor broken.
Bench temperature sensor short
-25
circuit.
-26
Humidity sensor broken.
-27
Humidity sensor short-circuiting.
-30
Thermal fuse defective.
No function

6.1. Version display

By simultaneously pressing the
software version number of the power unit is displayed on the operating unit for
3 seconds. The number "14" appears on the 7 segment display of the operating
unit, for example.
Rectification/cause
No operating unit connected or
poor contact.
Verify contact to operating unit.
Defective temperature sensor or
poor contact.
Defective temperature sensor or
short circuit.
Defective temperature sensor or
poor contact.
Defective temperature sensor or
short circuit.
Defective humidity sensor or
poorly/wrongly connected.
Defective humidity sensor, poor-
ly/wrongly connected or short
circuit.
Defective heater sensor, poor
contact or thermal fuse not con-
nected. Inform service!
Power supply for lighting and
electronics missing (See page
36, point 6).
,
and
7
6
4
keys in stand-by mode, the
p. 30/42